Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 220

The DOI matches its Crossref record.

Faster and safer? FLASH ultra-high dose rate in radiotherapy

Open access
Durante, Marco, Brauer-Krisch, Elke, Hill, Mark · 2017 · The British Journal of Radiology

Abstract

Recent results from the Franco-Swiss team of Institute Curie and Centre Hospitalier Universitaire Vaudois demonstrate a remarkable sparing of normal tissue after irradiation at ultra-high dose rate (>40 Gy s−1). The “FLASH” radiotherapy maintains tumour control level, suggesting that ultra-high dose rate can substantially enhance the therapeutic window in radiotherapy. The results have been obtained so far only with 4–6 MeV electrons in lung and brain mouse model. Nevertheless, they have attracted a great attention for the potential clinical applications. Oxygen depletion had been discussed many years ago as a possible mechanism for reduction of the damage after exposure to ultra-high dose rate. However, the mechanism underlying the effect observed in the FLASH radiotherapy remains to be elucidated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/bjr.20170628

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 220

Metadata

Authors
Durante, M., Brauer-Krisch, E., & Hill, M.
Venue
The British Journal of Radiology
Published
2017-11-27
Volume
91
Issue
1082
Pages
20170628
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2769131763
Cited by
220
References
0
FWCI
14.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Faster and safer? FLASH ultra-high dose rate in radiotherapy. https://app.cochat.ai/papers/10.1259/bjr.20170628
The paper
Durante, M., Brauer-Krisch, E., & Hill, M. (2017). Faster and safer? FLASH ultra-high dose rate in radiotherapy. The British Journal of Radiology. https://doi.org/10.1259/bjr.20170628

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.