High intensity focused ultrasound: surgery of the future?
Abstract
For 50 years, high intensity focused ultrasound (HIFU) has been a subject of interest for medical research. HIFU causes selective tissue necrosis in a very well defined volume, at a variable distance from the transducer, through heating or cavitation. Over the past decade, the use of HIFU has been investigated in many clinical settings. This literature review aims to summarize recent advances made in the field. A Medline-based literature search (1965-2002) was conducted using the keywords "HIFU" and "high intensity focused ultrasound". Additional literature was obtained from original papers and published meeting abstracts. The most abundant clinical trial data comes from studies investigating its use in the treatment of prostatic disease, although early research looked at applications in neurosurgery. More recently horizons have been broadened, and the potential of HIFU as a non-invasive surgical tool has been demonstrated in many settings including the treatment of tumours of the liver, kidney, breast, bone, uterus and pancreas, as well as conduction defects in the heart, for surgical haemostasis, and the relief of chronic pain of malignant origin. Further clinical evaluation will follow, but recent technological development suggests that HIFU is likely to play a significant role in future surgical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Self-citationCroissant, J. G., Fatieiev, Y., Almalik, A., & Khashab, N. M. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700831 · Cited by 594
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
Mimicking the Cell: Bio-Inspired Functions of Supramolecular Assemblies
Tu, Y., Peng, F., Adawy, A., Men, Y., Abdelmohsen, L. K. E. A., & Wilson, D. A. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00344 · Cited by 316
Metadata
- Authors
- Kennedy, J. E., ter Haar, G. R., & Cranston, D.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-09
- Volume
- 76
- Issue
- 909
- Pages
- 590-599
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2104377141
- Cited by
- 709
- References
- 0
- FWCI
- 14.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High intensity focused ultrasound: surgery of the future? https://app.cochat.ai/papers/10.1259/bjr/17150274
- The paper
- Kennedy, J. E., ter Haar, G. R., & Cranston, D. (2003). High intensity focused ultrasound: surgery of the future? The British Journal of Radiology. https://doi.org/10.1259/bjr/17150274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.