Assessment of paediatric CT dose indicators for the purpose of optimisation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objectives: To establish local diagnostic reference levels (LDRLs) at the Royal Children's Hospital (RCH) Melbourne, Parkville, Australia, for typical paediatric CT examinations and compare these with international diagnostic reference levels (DRLs) to benchmark local practice. In addition, the aim was to develop a method of analysing local scan parameters to enable identification of areas for optimisation. Methods: A retrospective audit of patient records for paediatric CT brain, chest and abdomen/pelvis examinations was undertaken. Demographic information, examination parameters and dose indicators—volumetric CT dose index (CTDIvol) and dose–length product (DLP)—were collected for 220 patients. LDRLs were derived from mean survey values and the effective dose was estimated from DLP values. The normalised CTDIvol values, mAs values and scan length were analysed to better identify parameters that could be optimised. Results: The LDRLs across all age categories were 18–45 mGy (CTDIvol) and 250–700 mGy cm (DLP) for brain examinations; 3–23 mGy (CTDIvol) and 100–800 mGy cm (DLP) for chest examinations; and 4–15 mGy (CTDIvol) and 150–750 mGy cm (DLP) for abdomen/pelvis examinations. Effective dose estimates were 1.0–1.6 mSv, 1.8–13.0 mSv and 2.5–10.0 mSv for brain, chest and abdomen/pelvis examinations, respectively. Conclusion: The RCH mean CTDIvol and DLP values are similar to or lower than international DRLs. Use of low-kilovoltage protocols for body imaging in younger patients reduced the dose considerably. There exists potential for optimisation in reducing body scan lengths and justifying the selection of reference mAs values. The assessment method used here proved useful for identifying specific parameters for optimisation. Advances in knowledge: Assessment of individual CT parameters in addition to comparison with DRLs enables identification of specific areas for CT optimisation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 1×
“CT currently accounts for the largest contribution to population dose from medical procedures [2], and several studies have shown that the use of CT is increasing, including imaging of children [3–6].”
Background
Cited by
Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study
Matsunaga, Y., Kawaguchi, A., Kobayashi, K., Kobayashi, M., Asada, Y., Minami, K., Suzuki, S., & Chida, K. (2016) · The British Journal of Radiology · doi:10.1259/bjr.20150671 · Cited by 29
Diagnostic reference levels in low- and middle-income countries: early “ALARAm” bells?
Meyer, S., Groenewald, W. A., & Pitcher, R. D. (2017) · Acta Radiologica · doi:10.1177/0284185116658681 · Cited by 24
Garba, I., & Engel-Hills, P. (2025) · Radiography · doi:10.1016/j.radi.2024.09.058 · Cited by 4
Metadata
- Authors
- Brady, Z., Ramanauskas, F., Cain, T. M., & Johnston, P. N.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-11-01
- Volume
- 85
- Issue
- 1019
- Pages
- 1488-1498
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2083197293
- Cited by
- 74
- References
- 1
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of paediatric CT dose indicators for the purpose of optimisation. https://app.cochat.ai/papers/10.1259/bjr/28015185
- The paper
- Brady, Z., Ramanauskas, F., Cain, T. M., & Johnston, P. N. (2012). Assessment of paediatric CT dose indicators for the purpose of optimisation. The British Journal of Radiology. https://doi.org/10.1259/bjr/28015185
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.