Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. METHODS: The study sample comprised 70 teeth (from the Institut d'Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D® CBCT (Carestream Health, Inc., Marne-la-Vallée, France), which has two voxel sizes: 200 µm (CBCT 200 µm group) and 300 µm (CBCT 300 µm group). These teeth had also been scanned with the KODAK 9000 3D® CBCT (Carestream Health, Inc.) (CBCT 76 µm group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Brüttisellen, Switzerland) (micro-CT 41 µm group) considered as references. After semi-automatic segmentation with AMIRA® software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. RESULTS: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 µm and 300 µm groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 µm group relative to the two reference groups (Passing-Bablok method). CONCLUSIONS: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Health Measurement Scales: A Practical Guide To Their Development And Use
Streiner, D. L., & Norman, G. R. (2003) · doi:10.1093/oso/9780198528470.001.0001 · Cited by 1,460
Comparison of cone beam computed tomography imaging with physical measures
Stratemann, S., Huang, J., Maki, K., Aj, M., & Hatcher, D. C. (2008) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/31349994 · Cited by 312 · cited 1×
“advantage of being a measuring instrument.(23,24) The accuracy of the measurement and its clinical significance must be considered in the context of each study.”
BackgroundConsiderations in the use of cone-beam computed tomography for buccal bone measurements
Molen, A. (2010) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2010.01.015 · Cited by 220 · cited 2×
“The spatial resolution is affected by the partial volume effect, which has repercussions on the image quality.(20,21) CBCT devices that have a high spatial resolution are less affected by partial volume effect as their voxel sizes are smaller.”
BackgroundOperational Principles for Cone-Beam Computed Tomography
Hatcher, D. C. (2010) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2010.0359 · Cited by 219
Cone beam CT in dental practice
Dawood, A., Patel, S., & Brown, J. E. (2009) · BDJ · doi:10.1038/sj.bdj.2009.560 · Cited by 201
Ferrante, L., & Cameriere, R. (2009) · International Journal of Legal Medicine · doi:10.1007/s00414-009-0349-4 · Cited by 132 · cited 3×
“CBCT 200 mm and CBCT 300 mm groups: Data for slices of a random sample of 20 teeth were re-examined 1 week after the initial examination to test intraexaminer consistency using the ICC.15 The ICC was also calculated to assess interexaminer reproducibility, again using a random sample of 20 teeth.”
MethodInfluentialKamburoğlu, K., & Kursun, S. (2010) · International Endodontic Journal · doi:10.1111/j.1365-2591.2010.01749.x · Cited by 118 · cited 1×
“The important influence of voxel size on the quality of CBCT images and on scanning and reconstruction times is already acknowledged.(13) However, data are still lacking on the effects of voxel size on the metric accuracy of reconstructions.”
BackgroundAccuracy of 3D Reconstructions Based on Cone Beam Computed Tomography
Maret, D., Molinier, F., Braga, J., Peters, O. A., Telmon, N., Treil, J., Inglèse, J. M., Cossié, A., Kahn, J. L., & Sixou, M. (2010) · Journal of Dental Research · doi:10.1177/0022034510378011 · Cited by 72 · cited 5×
“We showed in an earlier study that the volumes obtained with CBCT 76 mm were similar to those from micro-CT 41 mm.(7) The Kodak 9000 3D provided submillimetre isotropic voxel resolution that was the closest to that given by micro-CT.”
BackgroundMethodSelf-citationTechnical note: Compatibility of microtomographic imaging systems for dental measurements
Olejniczak, A. J., Tafforeau, P., Smith, T. M., Temming, H., & Hublin, J. (2007) · American Journal of Physical Anthropology · doi:10.1002/ajpa.20615 · Cited by 62
Cited by
Feature-based volumetric defect classification in metal additive manufacturing
Poudel, A., Yasin, M. S., Ye, J., Liu, J., Vinel, A., Shao, S., & Shamsaei, N. (2022) · Nature Communications · doi:10.1038/s41467-022-34122-x · Cited by 170
Metadata
- Authors
- Maret, D., Telmon, N., Peters, O. A., Lepage, B., Treil, J., Inglese, J. M., Peyre, A., Kahn, J. L., & Sixou, M.
- Venue
- Dentomaxillofacial Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-11-19
- Volume
- 41
- Issue
- 8
- Pages
- 649-655
- ISSN
- 0250-832X (ISSN-L)
- OpenAlex
- W4240262069
- Cited by
- 165
- References
- 12
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT. https://app.cochat.ai/papers/10.1259/dmf/81804525
- The paper
- Maret, D., Telmon, N., Peters, O. A., Lepage, B., Treil, J., Inglese, J. M., Peyre, A., Kahn, J. L., & Sixou, M. (2012). Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT. Dentomaxillofacial Radiology. https://doi.org/10.1259/dmf/81804525
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.