Adsorption, Kinetic and Equilibrium Studies of Cr(VI) by Hazelnut Shell Activated Carbon
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The adsorption of chromium(VI) from aqueous solutions on to hazelnut shell activated carbon (HSAC) was investigated. The adsorption was carried out by varying parameters such as the agitation time, the initial solution pH, the initial Cr(VI) concentration and the temperature. The experimental data were well fitted by the pseudo-first-order kinetic model allowing the rate constants to be evaluated. The Langmuir isotherm provided the best correlation for the adsorption of Cr(VI) onto the activated carbon. The adsorption of Cr(VI) was pH-dependent. The adsorption capacity as calculated from the Langmuir isotherm was 170 mg/g at an initial pH of 1.0 for a Cr(VI) solution of 1000 mg/l concentration. Thermodynamic parameters were evaluated, indicating that the adsorption was endothermic and involved monolayer adsorption of Cr(VI).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Low-cost adsorbents for heavy metals uptake from contaminated water: a review
Babel, S. (2003) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(02)00263-7 · Cited by 3,444 · cited 1×
“Many reports have appeared on the development of low-cost activated carbon adsorbents from cheaper and readily available materials (Babel and Kurniawan 2003; Bailey et al. 1999).”
Background
Cited by
Activated carbons and low cost adsorbents for remediation of tri- and hexavalent chromium from water
Mohan, D., & Pittman Jr., C. U. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.06.060 · Cited by 1,855
Biosorption of heavy metal ions using wheat based biosorbents – A review of the recent literature
Farooq, U., Kozinski, J. A., Khan, M. A., & Athar, M. (2010) · Bioresource Technology · doi:10.1016/j.biortech.2010.02.030 · Cited by 875
Kobya, M., Demirbas, E., Senturk, E., & Ince, M. (2005) · Bioresource Technology · doi:10.1016/j.biortech.2004.12.005 · Cited by 871
Self-citationRemoval of hexavalent chromium-contaminated water and wastewater: A review
Owlad, M., Aroua, M. K., Daud, W. A. W., & Baroutian, S. (2009) · Water, Air, and Soil Pollution · doi:10.1007/s11270-008-9893-7 · Cited by 820
Engineered nanomaterials for water treatment and remediation: Costs, benefits, and applicability
Adeleye, A. S., Conway, J. R., Garner, K., Huang, Y., Su, Y., & Keller, A. A. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.10.105 · Cited by 809
Metadata
- Authors
- Kobya, M.
- Venue
- Adsorption Science & Technology
- Publisher
- SAGE Publications
- Published
- 2004-02
- Volume
- 22
- Issue
- 1
- Pages
- 51-64
- ISSN
- 0263-6174 (ISSN-L)
- 2048-4038
- OpenAlex
- W2125557510
- Cited by
- 181
- References
- 1
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.