Applications of FRP Composites in Concrete Columns
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
One of the most promising applications of fiber reinforced polymer (FRP) composites is in reinforced concrete columns. This paper provides a review of recent research in this area. Based on the literature available, it is found that most applications and research are focused on the FRP retrofit or repair of existing reinforced concrete columns primarily for improved ductility. Some recent research efforts have been directed to the new design of columns using FRP tubes or FRP bars. The use of FRP tubes is reviewed in comparison to previous research on concrete filled steel tubular (CFT) structures and the tubed structures. It is more likely favorable for the FRP tube or rebar to be used as transverse reinforcement of concrete columns for better ductility needed for seismic design. A new concept by the author on confined concrete filled tubular (CCFT) columns is also introduced along with promising test results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Behavior of Concrete Columns Confined by Fiber Composites
Mirmiran, A., & Shahawy, M. A. (1997) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1997)123:5(583 · Cited by 828
Strength and Ductility of Concrete Columns Externally Reinforced With Fiber Composite Straps
Saadatmanesh, H., Ehsani, M. R., & Li, M.-Y. (1994) · ACI Structural Journal · doi:10.14359/4151 · Cited by 542 · cited 2×
“Several composite jacketing systems have been developed and validated in laboratory or field conditions (Matsuda et al. 1990; Saadatmanesh et al. 1994; Seible et al. 1995; Teng et al. 2002; Xiao et al. 1996, 2000).”
BackgroundFRP-encased concrete as a structural material
Fardis, M. N., & Khalili, H. H. (1982) · Magazine of Concrete Research · doi:10.1680/macr.1982.34.121.191 · Cited by 309 · cited 1×
“Fardis and Khalili (1982) tested five 76 × 152 × 1220 mm plain concrete beam-columns wrapped with glass fibers.”
Method
Cited by
Hollaway, L. C. (2010) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2010.04.062 · Cited by 1,297
Theoretical Model for Fiber-Reinforced Polymer-Confined Concrete
Teng, J. G., Huang, Y. L., Lam, L., & Ye, L. P. (2007) · Journal of Composites for Construction · doi:10.1061/(asce)1090-0268(2007)11:2(201 · Cited by 600
Haj Seiyed Taghia, S. A., Darvishvand, H. R., & Ebrahimi, M. (2020) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001760 · Cited by 4
Metadata
- Authors
- Xiao, Y.
- Venue
- Advances in Structural Engineering
- Publisher
- SAGE Publications
- Published
- 2004-08
- Volume
- 7
- Issue
- 4
- Pages
- 335-343
- ISSN
- 1369-4332 (ISSN-L)
- 2048-4011
- OpenAlex
- W615056131
- Cited by
- 175
- References
- 3
- FWCI
- 17.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.