Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: ApneaLink (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL's usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a selected group of people with clinical suspicion of OSA, using both automatic and manual scoring and comparing the results with those obtained for polysomnography (PSG). MATERIAL/METHODS: Simultaneous overnight recordings of in-laboratory PSG and AL were performed for 95 patients (mean age 46.3 ± 12.6 yr) with a high clinical suspicion of OSA. PSG was scored manually according to the American Academy of Sleep Medicine (AASM) guidelines. AL data were analyzed automatically using a manufacturer-provided computerized algorithm. Manual scoring of the AL flow signal followed the AASM guidelines for reduction in flow. RESULTS: The mean apnea hypopneas index (AHI) for PSG was 34.1 ± 32.4/hr. The AL Auto-AHI was 20.1 ± 25.2/h, and the AL Manual-AHI was 39.5 ± 30.4/h. The Pearson correlation coefficients were r=0.883 between PSG-AHI and AL Auto-AHI, and r=0.966 between PSG-AHI and AL Manual-AHI. At AHIs of 5, 10, 15, and 30, the AL Auto sensitivity/specificity was 0.79/0.68, 0.70/0.89, 0.64/0.94 and 0.63/0.98, and the AL Manual sensitivity/specificity was 1.00/0.43, 1.00/0.56, 0.98/0.58 and 1.00/0.80. CONCLUSIONS: Combining auto and manual scoring of data (automatic scoring followed by manual scoring) recorded by single-channel ApneaLink provides good diagnostic agreement with conventional PSG recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
Diagnostic tests 4: likelihood ratios
Deeks, J. J., & Altman, D. G. (2004) · BMJ · doi:10.1136/bmj.329.7458.168 · Cited by 1,600
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Cited by
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Abrahamyan, L., Sahakyan, Y., Chung, S., Pechlivanoglou, P., Bielecki, J., Carcone, S. M., Rac, V. E., Fitzpatrick, M., & Krahn, M. (2018) · Sleep and Breathing · doi:10.1007/s11325-017-1615-1 · Cited by 67
Savage, H. O., Khushaba, R. N., Zaffaroni, A., Colefax, M., Farrugia, S., Schindhelm, K., Teschler, H., Weinreich, G., Grueger, H., Neddermann, M., et al. (2016) · ESC Heart Failure · doi:10.1002/ehf2.12086 · Cited by 30
Araújo, I., Marques, F., André, S., Araújo, M., Marques, S., Ferreira, R., Moniz, P., Proença, M., Borrego, P., & Fonseca, C. (2018) · Sleep and Breathing · doi:10.1007/s11325-017-1607-1 · Cited by 18
Metadata
- Authors
- BaHammam, A. S., Sharif, M., Gacuan, D. E., & George, S.
- Venue
- Medical Science Monitor
- Published
- 2011
- Volume
- 17
- Issue
- 2
- Pages
- MT13-MT19
- ISSN
- 1234-1010 (ISSN-L)
- OpenAlex
- W2155297297
- Cited by
- 39
- References
- 4
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea. https://app.cochat.ai/papers/10.12659/msm.881379
- The paper
- BaHammam, A. S., Sharif, M., Gacuan, D. E., & George, S. (2011). Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea. Medical Science Monitor. https://doi.org/10.12659/msm.881379
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.