CoChat

Comparison of upper‐airway evaluations during wakefulness and sleep

Tucker Woodson, B., Wooten, Marvin R. · 1994 · The Laryngoscope
Cited by 76

The DOI matches its Crossref record.

Abstract

The location of upper‐airway obstruction during sleep has been predicted by using waking measures that include physical examination and endoscopic Müller's maneuver. However, this prediction remains speculative. To objectively evaluate these clinical measures, 22 patients with severe obstructive sleep apnea had upper‐airway studies during nonsedated sleep with solid‐state manometry and videoendoscopy. Objective tongue‐base obstruction was measured with four methods, each identifying a different aspect of airway collapse during sleep. Manometry identified tongue obstruction during (1) early and (2) late inspiration, and videoendoscopy identified severe collapse without complete obstruction during (3) late inspiration, and (4) expiration. Twenty‐eight waking upper‐airway characteristics measured at waking clinical and endoscopic examination were then compared between patients with and without tongue‐base segment obstruction to identify characteristics that would discriminate tongue‐base obstruction. The results demonstrated that tongue‐base/hypopharyngeal pathology during wakefulness was present on clinical examination in 19 of 22 (86%) patients. Objectively, during sleep tongue‐base obstruction occurred on manometric early inspiration in 5 of 21 (24%) patients, on manometric late inspiration in 11 of 21 (52%), on endoscopic late inspiration in 14 of 19 (74%), and on endoscopic expiration in 8 of 19 (42%). Patients with tongue‐base obstruction during sleep were primarily discriminated on waking examination by nonobstructive upper oropharyngeal features (p<0.10). Near‐total collapse of the tongue base on supine endoscopy was the only characteristic associated with tongue‐base obstruction during sleep. Müller's maneuver did not discriminate patient groups. Results indicate that the incidence of tongue‐base abnormalities measured during sleep varies significantly depending on the measure used. This variability may contribute to variability in surgical success rates. Identification of airway pathology relevant to sleep‐related breathing disorders may require new methods of evaluation and a better understanding of upper‐airway biomechanics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1288/00005537-199407000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 76

Metadata

Authors
Tucker Woodson, B., & Wooten, M. R.
Venue
The Laryngoscope
Publisher
Wiley
Published
1994-07
Volume
104
Issue
7
Pages
821-828
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2006726091
Cited by
76
References
0
FWCI
1.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of upper‐airway evaluations during wakefulness and sleep. https://app.cochat.ai/papers/10.1288/00005537-199407000-00007
The paper
Tucker Woodson, B., & Wooten, M. R. (1994). Comparison of upper‐airway evaluations during wakefulness and sleep. The Laryngoscope. https://doi.org/10.1288/00005537-199407000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.