CoChat

Association of Biomarkers of Systemic Inflammation with Organic Components and Source Tracers in Quasi-Ultrafine Particles

Open access
Delfino, Ralph J., Staimer, Norbert, Tjoa, Thomas, Arhami, Mohammad, Polidori, Andrea, Gillen, Daniel L., Kleinman, Michael T., Schauer, James J., Sioutas, Constantinos · 2010 · Environmental Health Perspectives
Cited by 152

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Abstract Background Evidence is needed regarding the air pollutant components and their sources responsible for associations between particle mass concentrations and human cardiovascular outcomes. We previously found associations between circulating biomarkers of inflammation and mass concentrations of quasi-ultrafine particles ≤ 0.25 μm in aerodynamic diameter (PM0.25) in a panel cohort study of 60 elderly subjects with coronary artery disease living in the Los Angeles Basin. Objectives We reassessed biomarker associations with PM0.25 using new particle composition data. Methods Weekly biomarkers of inflammation were plasma interleukin-6 (IL-6) and soluble tumor necrosis factor-α receptor II (sTNF-RII) (n = 578). Exposures included indoor and outdoor community organic PM0.25 constituents [polycyclic aromatic hydrocarbons (PAHs), hopanes, n-alkanes, organic acids, water-soluble organic carbon, and transition metals]. We analyzed the relation between biomarkers and exposures with mixed-effects models adjusted for potential confounders. Results Indoor and outdoor PAHs (low-, medium-, and high-molecular-weight PAHs), followed by hopanes (vehicle emissions tracer), were positively associated with biomarkers, but other organic components and transition metals were not. sTNF-RII increased by 135 pg/mL [95% confidence interval (CI), 45–225 pg/mL], and IL-6 increased by 0.27 pg/mL (95% CI, 0.10–0.44 pg/mL) per interquartile range increase of 0.56 ng/m3 outdoor total PAHs. Two-pollutant models of PM0.25 with PAHs showed that nominal associations of IL-6 and sTNF-RII with PM0.25 mass were completely confounded by PAHs. Vehicular emission sources estimated from chemical mass balance models were strongly correlated with PAHs (R = 0.71). Conclusions Traffic emission sources of organic chemicals represented by PAHs are associated with increased systemic inflammation and explain associations with quasi-ultrafine particle mass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1289/ehp.0901407

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 152

Metadata

Authors
Delfino, R. J., Staimer, N., Tjoa, T., Arhami, M., Polidori, A., Gillen, D. L., Kleinman, M. T., Schauer, J. J., & Sioutas, C.
Venue
Environmental Health Perspectives
Published
2010-06
Volume
118
Issue
6
Pages
756-762
ISSN
  • 0091-6765 (ISSN-L)
  • 1552-9924
OpenAlex
W1964735517
Cited by
152
References
1
FWCI
7.90
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.