Continuous Positive Airway Pressure Improves Daytime Baroreflex Sensitivity and Nitric Oxide Production in Patients with Moderate to Severe Obstructive Sleep Apnea Syndrome
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Individuals with obstructive sleep apnea syndrome (OSAS) are at high risk for cardiovascular morbidity and mortality. The effects of OSAS severity and nocturnal continuous positive airway pressure (CPAP) on daytime baroreflex sensitivity (BRS) and nitric oxide (NO) production were investigated in OSAS patients. Fifty-one consecutive males with OSAS and 29 age-matched healthy men underwent the Valsalva test and standard polysomnography. Patients with an apnea-hypopnea index (AHI) of >or=20 episodes per hour were randomized to receive CPAP treatment for 3 months (n=14) or no such treatment (n=19). The BRS index measured from the overshoot phase (phase IV) of the Valsalva maneuver and plasma NO concentration were significantly lower, whereas the AHI, oxygen desaturation time, arousal index, percentage of sleep stage 1, and systolic blood pressure were significantly greater, in patients with an AHI of >or=20/h than in those with an AHI of <20/h or in controls. The 24-h urinary excretion of norepinephrine was significantly reduced and the plasma NO concentration was significantly increased after one night of CPAP. The BRS index for phase IV and the Valsalva ratio were significantly increased in the CPAP group after the 3-month treatment period but remained unchanged in the non-CPAP group of OSAS patients. The daytime BRS index and NO production were thus inversely related to the severity of OSAS, and successful CPAP treatment improved these parameters in patients with moderate to severe OSAS. CPAP may therefore reduce the risk of cardiovascular complications due to endothelial dysfunction or increased sympathetic activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
Nieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
Rovere, M. T. L., Bigger, J. T., Marcus, F. I., Mortara, A., & Schwartz, P. J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11144-8 · Cited by 3,120
Sleep-disordered Breathing and Cardiovascular Disease
SHAHAR, E., WHITNEY, C. W., REDLINE, S., LEE, E. T., NEWMAN, A. B., JAVIER NIETO, F., O'CONNOR, G. T., BOLAND, L. L., SCHWARTZ, J. E., & SAMET, J. M. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.2001008 · Cited by 2,901
Sympathetic neural mechanisms in obstructive sleep apnea.
Somers, V. K., Dyken, M. E., Clary, M. P., & Abboud, F. M. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118235 · Cited by 2,527
Sympathetic-Nerve Activity during Sleep in Normal Subjects
Somers, V. K., Dyken, M. E., Mark, A. L., & Abboud, F. M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302043280502 · Cited by 1,574 · cited 1×
“compared with those apparent during wakefulness (9, 27).”
ResultOgawa, Y., Kanbayashi, T., Saito, Y., Takahashi, Y., Kitajima, T., Takahashi, K., Hishikawa, Y., & Shimizu, T. (2003) · SLEEP · doi:10.1093/sleep/26.8.986 · Cited by 235 · cited 1×
“function curve to higher levels of pressure (40, 46).”
BackgroundCardiac Hypertrophy in Obstructive Sleep Apnea Syndrome
Noda, A., Okada, T., Yasuma, F., Nakashima, N., & Yokota, M. (1995) · Chest · doi:10.1378/chest.107.6.1538 · Cited by 155
Self-citation
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
on behalf of The Japanese Society of Hypertension Committee for Guidelines for the Management of Hypertension, Ogihara, T., Kikuchi, K., Matsuoka, H., Fujita, T., Higaki, J., Horiuchi, M., Imai, Y., Imaizumi, T., Ito, S., et al. (2014) · Hypertension Research · doi:10.1038/hr.2014.68 · Cited by 1,385
Mechanisms of vascular damage in obstructive sleep apnea
Kohler, M., & Stradling, J. R. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.145 · Cited by 513
Bratton, D. J., Gaisl, T., Wons, A. M., & Kohler, M. (2015) · JAMA · doi:10.1001/jama.2015.16303 · Cited by 362
Effect of CPAP on Blood Pressure in Patients With OSA/Hypopnea
Fava, C., Dorigoni, S., Dalle Vedove, F., Danese, E., Montagnana, M., Guidi, G. C., Narkiewicz, K., & Minuz, P. (2014) · Chest · doi:10.1378/chest.13-1115 · Cited by 305
Metadata
- Authors
- NODA, A., NAKATA, S., KOIKE, Y., MIYATA, S., KITAICHI, K., NISHIZAWA, T., NAGATA, K., YASUMA, F., MUROHARA, T., & YOKOTA, M.
- Venue
- Hypertension Research
- Publisher
- Japanese Society of Hypertension
- Published
- 2007
- Volume
- 30
- Issue
- 8
- Pages
- 669-676
- ISSN
- 0916-9636 (ISSN-L)
- 1348-4214
- OpenAlex
- W2081975264
- Cited by
- 114
- References
- 10
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.