Low strength concrete members externally confined with FRP sheets
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
In this paper axial loading tests on low strength concrete members, which were confined with various thickness of carbon fiber reinforced polymer (CFRP) composite sheets are described. Totally 46 specimens with circular, square and rectangular cross-sections with unconfined concrete compressive strengths between 6 and 10 MPa were included in the test program. During the tests, a photogrammetrical deformation measurement technique was also used, as well as conventional measurement techniques. The contribution of external confinement with CFRP composite sheets to the compressive behavior of the specimens with low strength concrete is evaluated quantitatively, in terms of strength, longitudinal and lateral deformability and energy dissipation. The effects of width/depth ratios and the corner radius of the specimens with rectangular cross-section on the axial behavior were also examined. It was seen that the effectiveness of the external confinement with CFRP composite sheets is much more pronounced, when the unconfined concrete compressive strength is relatively lower. It was also found that the available analytical expressions proposed for normal or high strength concrete confined by CFRP sheets could not predict the strength and deformability of CFRP confined low strength concrete accurately. New expressions are proposed for the compressive strength and the ultimate axial strain of CFRP confined low strength concrete.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theoretical Stress‐Strain Model for Confined Concrete
Mander, J. B., Priestley, M. J. N., & Park, R. (1988) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1988)114:8(1804 · Cited by 8,454
Observed Stress‐Strain Behavior of Confined Concrete
Mander, J. B., Priestley, M. J. N., & Park, R. (1988) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1988)114:8(1827 · Cited by 1,000
Strength and Ductility of Confined Concrete
Saatçioğlu, M., & Razvi, S. R. (1992) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1992)118:6(1590 · Cited by 985
Behavior of Concrete Columns Confined by Fiber Composites
Mirmiran, A., & Shahawy, M. A. (1997) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1997)123:5(583 · Cited by 828
Design-Oriented Stress-Strain Model for FRP-Confined Concrete in Rectangular Columns
Lam, L., & Teng, J. G. (2003) · Journal of Reinforced Plastics and Composites · doi:10.1177/0731684403035429 · Cited by 745
Effect of Column Parameters on FRP-Confined Concrete
Mirmiran, A., Shahawy, M. A., Samaan, M., Echary, H. E., Mastrapa, J. C., & Pico, O. G. (1998) · Journal of Composites for Construction · doi:10.1061/(asce)1090-0268(1998)2:4(175 · Cited by 707
Spoelstra, M. R., & Monti, G. (1999) · Journal of Composites for Construction · doi:10.1061/(asce)1090-0268(1999)3:3(143 · Cited by 654
Strength and Ductility of Concrete Columns Externally Reinforced With Fiber Composite Straps
Saadatmanesh, H., Ehsani, M. R., & Li, M.-Y. (1994) · ACI Structural Journal · doi:10.14359/4151 · Cited by 542
Strength Models for Fiber-Reinforced Plastic-Confined Concrete
Lam, L., & Teng, J. G. (2002) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2002)128:5(612 · Cited by 359
FRP jacketed concrete under uniaxial compression
Nanni, A., & Bradford, N. M. (1995) · Construction and Building Materials · doi:10.1016/0950-0618(95)00004-y · Cited by 334
Cited by
Application of polymer composites in civil construction: A general review
Pendhari, S. S., Kant, T., & Desai, Y. M. (2008) · Composite Structures · doi:10.1016/j.compstruct.2007.06.007 · Cited by 362
Haj Seiyed Taghia, S. A., Darvishvand, H. R., & Ebrahimi, M. (2020) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001760 · Cited by 4
Metadata
- Authors
- Ilki, A., Kumbasar, N., & Koc, V.
- Venue
- Structural Engineering and Mechanics
- Publisher
- Techno-Press
- Published
- 2004-08-25
- Volume
- 18
- Issue
- 2
- Pages
- 167-194
- ISSN
- 1225-4568 (ISSN-L)
- OpenAlex
- W2078907356
- Cited by
- 163
- References
- 13
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.