A new method for optimal selection of sensor location on a high-rise building using simplified finite element model
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Deciding on an optimal sensor placement (OSP) is a common problem encountered in many engineering applications and is also a critical issue in the construction and implementation of an effective structural health monitoring (SHM) system. The present study focuses with techniques for selecting optimal sensor locations in a sensor network designed to monitor the health condition of Dalian World Trade Building which is the tallest in the northeast of China. Since the number of degree-of-freedom (DOF) of the building structure is too large, multi-modes should be selected to describe the dynamic behavior of a structural system with sufficient accuracy to allow its health state to be determined effectively. However, it's difficult to accurately distinguish the translational and rotational modes for the flexible structures with closely spaced modes by the modal participation mass ratios. In this paper, a new method of the OSP that computing the mode shape matrix in the weak axis of structure by the simplified multi-DOF system was presented based on the equivalent rigidity parameter identification method. The initial sensor assignment was obtained by the QR-factorization of the structural mode shape matrix. Taking the maximum off-diagonal element of the modal assurance criterion (MAC) matrix as a target function, one more sensor was added each time until the maximum off-diagonal element of the MAC reaches the threshold. Considering the economic factors, the final plan of sensor placement was determined. The numerical example demonstrated the feasibility and effectiveness of the proposed scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensor placement for on-orbit modal identification and correlation of large space structures
Kammer, D. C. (1991) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20635 · Cited by 935
Cited by
Computational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
Li, J., Hao, H., & Chen, Z. (2017) · Journal of Aerospace Engineering · doi:10.1061/(asce)as.1943-5525.0000550 · Cited by 44
An Improved Genetic Algorithm for Optimal Sensor Placement in Space Structures Damage Detection
Beygzadeh, S., Salajegheh, E., Torkzadeh, P., Salajegheh, J., & Naseralavi, S. S. (2014) · International Journal of Space Structures · doi:10.1260/0266-3511.29.3.121 · Cited by 25
Sensor Placement for Structural Damage Detection considering Measurement Uncertainties
Zhou, X.-Q., Xia, Y., & Hao, H. (2013) · Advances in Structural Engineering · doi:10.1260/1369-4332.16.5.899 · Cited by 17
“Meanwhile, Yi et al. (2011) proposed an optimal sensor placement by minimizing the maximum value of the off-diagonal elements of the modal assurance criterion matrix.”
Background
Metadata
- Authors
- Yi, T.-H., Li, H.-N., & Gu, M.
- Venue
- Structural Engineering and Mechanics
- Publisher
- Techno-Press
- Published
- 2011-03-25
- Volume
- 37
- Issue
- 6
- Pages
- 671-684
- ISSN
- 1225-4568 (ISSN-L)
- OpenAlex
- W2088441543
- Cited by
- 105
- References
- 1
- FWCI
- 36.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new method for optimal selection of sensor location on a high-rise building using simplified finite element model. https://app.cochat.ai/papers/10.12989/sem.2011.37.6.671
- The paper
- Yi, T.-H., Li, H.-N., & Gu, M. (2011). A new method for optimal selection of sensor location on a high-rise building using simplified finite element model. Structural Engineering and Mechanics. https://doi.org/10.12989/sem.2011.37.6.671
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.