An experimental study of vibration control of wind-excited high-rise buildings using particle tuned mass dampers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A particle tuned mass damper (PTMD) system is the combination of a traditional tuned mass damper (TMD) and a particle damper (PD). This paper presents the results of an experimental and analytical study of the damping performance of a PTMD attached to the top of a benchmark model under wind load excitation. The length ratio of the test model is 1:200. The vibration reduction laws of the system were explored by changing some system parameters (including the particle material, total auxiliary mass ratio, the mass ratio between container and particles, the suspending length, and wind velocity). An appropriate analytical solution based on the concept of an equivalent single-unit impact damper is presented. Comparison between the experimental and analytical results shows that, with the proper use of the equivalent method, reasonably accurate estimates of the dynamic response of a primary system under wind load excitation can be obtained. The experimental and simulation results show the robustness of the new damper and indicate that the damping performance can be improved by controlling the particle density, increasing the amount of particles, and aggravating the impact of particles etc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitigation of wind‐induced response of Shanghai Center Tower by tuned mass damper
Lu, X., & Chen, J. (2011) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.659 · Cited by 83
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Nonlinear dissipative devices in structural vibration control: A review
Lu, Z., Wang, Z., Zhou, Y., & Lu, X. (2018) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2018.02.052 · Cited by 501
Self-citationParticle impact dampers: Past, present, and future
Lu, Z., Wang, Z., Masri, S. F., & Lu, X. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2058 · Cited by 285
Self-citationA review of particle damping modeling and testing
Gagnon, L., Morandini, M., & Ghiringhelli, G. L. (2019) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2019.114865 · Cited by 159
“[106] both building tuned mass damper PD 1.”
Lu, X., Liu, Z., & Lu, Z. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.2033 · Cited by 115
Self-citation
Metadata
- Authors
- Lu, Z., Wang, D., Masri, S. F., & Lu, X.
- Venue
- Smart Structures and Systems
- Publisher
- Techno-Press
- Published
- 2016-07-25
- Volume
- 18
- Issue
- 1
- Pages
- 93-115
- ISSN
- 1738-1584 (ISSN-L)
- OpenAlex
- W2484797341
- Cited by
- 105
- References
- 1
- FWCI
- 23.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An experimental study of vibration control of wind-excited high-rise buildings using particle tuned mass dampers. https://app.cochat.ai/papers/10.12989/sss.2016.18.1.093
- The paper
- Lu, Z., Wang, D., Masri, S. F., & Lu, X. (2016). An experimental study of vibration control of wind-excited high-rise buildings using particle tuned mass dampers. Smart Structures and Systems. https://doi.org/10.12989/sss.2016.18.1.093
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.