CoChat

Numerical analysis of cell membrane perforation in on-chip microdroplet-based electroporation (Membrane perforation characteristics when electrodes are placed on the same plane)

NAKASHIMA, Kenji, MATSUYAMA, Fuminori, JOHNO, Yuuki, ISHII-TESHIMA, Miho, SHIBATA, Takayuki · 2021 · Transactions of the JSME (in Japanese)
Cited by 1

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

On-chip microdroplet-based electroporation is a newly developed process that enables droplet electroporation in a microfluidic device. If the process is to be realized at low cost, the electrode pair should be installed on the same plane. On the other hand, the electrode pair is installed as parallel plates in electroporation process with ordinary cuvettes. When the electroporation process is converted to a microfluidic device, the effect of electrode placement must be investigated because the electrode placement pattern is different from that of conventional electroporation. Therefore, numerical analysis of cell membrane perforation in micro rectangular channels was performed to support the design of an on-chip microdroplet-based electroporation system. The calculated geometry was given a state in which one cell was located in the center of the droplet. Since membrane perforation by a voltage pulse is a 1 μs time scale phenomenon, a numerical method was applied in which the electric field formation and membrane perforation are calculated in the same time step. The current conservation equation and the asymptotic Smoluchowski equation were coupled by the transmembrane voltage to calculate the time dependence. The calculation results showed that the position of high pore density on the cell membrane was slightly shifted compared to the case of electroporation by cuvette, but the position was almost ideal. And the pore density, electric field strength and transmembrane voltage distribution on the membrane showed accurate perforation locations and mechanisms. In addition, numerical analysis was also performed on the ideal parallel plane electrode assuming electroporation with a cuvette. It was shown that although the parallel planar electrode enables more efficient electroporation, the same planar electrode can also perforate the cell membrane at almost the same position. Finally, based on the results of 81 different calculations, the transitions in pore density and transmembrane voltage when cell is translocated are shown. The computing software COMSOL Multiphysics 5.4 on Windows OS was used on the workstation HP Z8 (CPU: Intel Xeon Gold 6128×2, Main memory: 96 GB).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1299/transjsme.20-00446

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 26

  1. Abdelmoez, M. N., Oguchi, Y., Ozaki, Y., Yokokawa, R., Kotera, H. and Shintaku, H., Distinct kinetics in electrophoretic extraction of cytoplasmic RNA from single cells, Analytical Chemistry, Vol. 92, No. 1 (2020), pp. 1485-1492.
  2. Alberts, B., Bray, D., Hopkin, K., Johnson, A., Lewis, J., Raff, M., Roberts, K. and Walter, P., Essential Cell Biology second edition (2005), p. 409, Nankodo (in Japanese).
  3. Chen, C., Smye, S. W., Robinson, M. P. and Evans, J. A., Membrane electroporation theories: a review, Medical and Biological Engineering and Computing, Vol. 44 (2006), pp. 5-14.
  4. Dermol-Cerne, J., Napotnik, T. B., Rebersek, M. and Miklavcic, D., Short microsecond pulses achieve homogeneous electroporation of elongated biological cells irrespective of their orientation in electric field, Scientific Reports (2020), 10:9149. · DOI
  5. Glaser, R. W., Leikin, S. L., Chernomordik, L. V., Pastushenko, V. F. and Sokirko, A. I., Reversible electrical breakdown of lipid bilayers: formation and evolution of pores, Biochimica et Biophysica Acta, Vol. 940 (1988), pp. 275-287. · DOI · Paper page
  6. Ishii-Teshima, M., Ushiroda, F., Itoh, Y., Furukawa, Y., Nagai, M., Numano, R. and Shibata, T., Development of microdroplet-based electroporation system for designing cellular functions (4th report)―Electrophoretic behavior of delivering DNA molecules into cell―, Proceedings of the Japan Society for Precision Engineering 2019 (2019), pp. 337-338 (in Japanese).
  7. Katsuki, S., Bacteria decontamination by pulsed power, Journal of Plasma and Fusion Research, Vol. 79, No. 1 (2003), pp. 20-25 (in Japanese). · doi:10.1585/jspf.79.20
  8. Kirsch, S. A. and Bockmann, R. A., Membrane pore formation in atomistic and coarse-grained simulations, Biochimica et Biophysica Acta, Vol. 1858 (2016), pp. 2266-2277.
  9. Kotnik, T. and Miklavcic, D., Theoretical evaluation of voltage inducement on internal membranes of biological cells exposed to electric fields, Biophysical Journal, Vol. 90 (2006), pp. 480-491.
  10. Kurita, H., Takahashi, S., Asada, A., Matsuo, M., Kishikawa, K., Mizuno, A. and Numano, R., Novel parallelized electroporation by electrostatic manipulation of a water-in-oil droplet as a microreactor, PLoS ONE, Vol. 10, No. 12 (2015), e0144254. · DOI · Paper page
  11. Leguebe, M., Silve, A., Mir, L. M. and Poignard, C., Conducting and permeable states of cell membrane submitted to high voltage pulses: mathematical and numerical studies validated by the experiments, Journal of Theoretical Biology, Vol. 360 (2014), pp. 83-94.
  12. Li, J. and Lin, H., Numerical simulation of molecular uptake via electroporation, Bioelectrochemistry, Vol. 82 (2011), pp. 10-21.
  13. Moen, E. K., Ibey, B. L., Beier, H. T. and Armani, A. M., Quantifying pulsed electric field-induced membrane nanoporation in single cells, Biochimica et Biophysica Acta, Vol. 1858, Issue 11 (2016), pp. 2795-2803.
  14. Moreaux, L., Pons, T., Dambrin, V., Blanchard-Desce, M. and Mertz, J., Electro-optic response of second-harmonic generation membrane potential sensors, Optics Letters, Vol. 28, No. 8 (2003), pp. 625-627.
  15. Nagle, J. F. and Tristram-Nagle, S., Structure of lipid bilayers, Biochimica et Biophysica Acta, Vol. 1469 (2000), pp. 159-195.
  16. Nishino, M., Matsuzaki, I., Musangile, F. Y., Takahashi, Y., Iwahashi, Y., Warigaya, K., Kinoshita, Y., Kojima, F. and Murata, S., Measurement and visualization of cell membrane surface charge in fixed cultured cells related with cell morphology, PLoS ONE, Vol. 15, No. 7 (2020), e0236373. · DOI
  17. Okita, K., Yamakawa, T., Matsumura, Y., Sato, Y., Amano, N., Watanabe, A., Goshima, N. and Yamanaka, S., An efficient nonviral method to generate integration-free human-induced pluripotent stem cells from cord blood and peripheral blood cells, Stem Cells, Vol. 31, No. 3 (2013), pp. 458-466.
  18. Poignard, C., Silve, A. and Wegner, L. H., Different approaches used in modeling of cell membrane electroporation, Handbook of Electroporation (2017), pp. 1019-1042, Springer International Publishing. · DOI
  19. Pucihar, G., Miklavcic, D. and Kotnik, T., A time-dependent numerical model of transmembrane voltage inducement and electroporation of irregularly shaped cells, IEEE Transactions on Biomedical Engineering, Vol. 56, No. 5 (2009), pp. 1491-1501.
  20. Rols, M. P., Gene delivery by electroporation in vitro: mechanisms, Handbook of Electroporation (2017), pp. 387-401, Springer International Publishing.
  21. Saito, K., Endo, R., Nozawa, Y., Minamitani, Y. and Fukata, H., A discussion of an applicable dielectric breakdown theory to the formation of pores on cells in the pulsed electric field sterilization, IEEJ Transactions on Fundamentals and Materials, Vol. 135, No. 6 (2015), pp. 341-346 (in Japanese). · doi:10.1541/ieejfms.135.341
  22. Schoenbach, K. H., Peterkin, F. E., Alden, R. W. and Beebe, S. J., The effect of pulsed electric fields on biological cells: experiments and applications (invited paper), IEEE Transactions on Plasma Science, Vol. 25, No. 2 (1997), pp. 284-292.
  23. Teissie, J., Critical electric field and transmembrane voltage for lipid pore formation in experiments, Handbook of Electroporation (2017a), pp. 25-43, Springer International Publishing. · DOI
  24. Teissie, J., Mechanistic description of membrane electropermeabilization, Handbook of Electroporation (2017b), pp. 451-472, Springer International Publishing. · DOI
  25. Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N. T., Warkiani, M. E. and Li, W., Fundamentals and applications of inertial microfluidics: a review, Lab on a Chip, Issue 1 (2016), pp. 10-34.
  26. Zimmermann, U., Pilwat, G., Holzapfel, C. and Rosenheck, K., Electrical hemolysis of human and bovine red blood cells, The Journal of Membrane Biology, Vol. 30, No. 2 (1976), pp. 135-152.

Cited by

See all 1

Metadata

Authors
NAKASHIMA, K., MATSUYAMA, F., JOHNO, Y., ISHII-TESHIMA, M., & SHIBATA, T.
Affiliations
  • National Institute of Technology, Sasebo College
  • Toyohashi University of Technology
Venue
Transactions of the JSME (in Japanese)
Published
2021
Volume
87
Issue
896
Pages
20-00446-20-00446
ISSN
2187-9761
Cited by
1
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.