Implant biomaterials: A comprehensive review
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Appropriate selection of the implant biomaterial is a key factor for long term success of implants. The biologic environment does not accept completely any material so to optimize biologic performance, implants should be selected to reduce the negative biologic response while maintaining adequate function. Every clinician should always gain a thorough knowledge about the different biomaterials used for the dental implants. This article makes an effort to summarize various dental bio-materials which were used in the past and as well as the latest material used now.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Contemporary Implant Dentistry
Misch, C. E. (1999) · Implant Dentistry · doi:10.1097/00008505-199901000-00012 · Cited by 1,368
Inspiration and application in the evolution of biomaterials
Huebsch, N., & Mooney, D. J. (2009) · Nature · doi:10.1038/nature08601 · Cited by 855
On implant surfaces: a review of current knowledge and opinions.
Wennerberg, A., & Albrektsson, T. O. (2010) · PubMed · Cited by 650
Zirconia Dental Implants: A Literature Review
Özkurt, Z., & Kazazoğlu, E. (2011) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-09-00079 · Cited by 347
An overview of the corrosion aspect of dental implants (titanium and its alloys)
Chaturvedi, T. P. (2009) · Indian Journal of Dental Research · doi:10.4103/0970-9290.49068 · Cited by 297
Osseointegration of zirconia implants compared with titanium: an in vivo study
Depprich, R., Zipprich, H., Ommerborn, M., Naujoks, C., Wiesmann, H.-P., Kiattavorncharoen, S., Lauer, H.-C., Meyer, U., Kübler, N. R., & Handschel, J. (2008) · Head & Face Medicine · doi:10.1186/1746-160x-4-30 · Cited by 292
Nonalloyed titanium as a bioinert metal--a review.
Tschernitschek, H., Borchers, L., & Geurtsen, W. (2005) · PubMed · Cited by 200
Meffert, R. M., Langer, B., & Fritz, M. E. (1992) · Journal of Periodontology · doi:10.1902/jop.1992.63.11.859 · Cited by 182
Fracture Resistance of Yttria‐Stabilized Zirconia Dental Implant Abutments
Adatia, N. D., Bayne, S. C., Cooper, L. F., & Thompson, J. Y. (2008) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2008.00378.x · Cited by 131
Biomaterials for Dental Implants: An Overview
Amarnath, G. S., Muddugangadhar, B. C., Tripathi, S., Suchismita, D., & Divya, M. S. (2011) · International Journal of Oral Implantology and Clinical Research · doi:10.5005/jp-journals-10012-1030 · Cited by 66
Carvalho, T. L. L., Araújo, C. A. C. A., Teófilo, J. M., & Brentegani, L. G. (1997) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0901-5027(05)80838-0 · Cited by 62
Cytotoxic effects of cobalt‐chromium alloys on fibroblasts derived from human gingiva
Arvidson, K., Cottler‐Fox, M., HAMMARLUND, E., & Friberg, U. (1987) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.1987.tb01853.x · Cited by 56
Cellular responses to implant materials: biological, physical and chemical factors.
Kawahara, H. (1983) · PubMed · Cited by 51
Cited by
Metallic Biomaterials: Current Challenges and Opportunities
Prasad, K., Bazaka, O., Chua, M., Rochford, M., Fedrick, L., Spoor, J., Symes, R., Tieppo, M., Collins, C., Cao, A., et al. (2017) · Materials · doi:10.3390/ma10080884 · Cited by 662
Current and emerging applications of 3D printing in medicine
Liaw, C.-Y., & Guvendiren, M. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7279 · Cited by 604
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Photopolymerizable Biomaterials and Light-Based 3D Printing Strategies for Biomedical Applications
Yu, C., Schimelman, J., Wang, P., Miller, K. L., Ma, X., You, S., Guan, J., Sun, B., Zhu, W., & Chen, S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00810 · Cited by 579
Biomedical Applications of Biodegradable Polyesters
Manavitehrani, I., Fathi, A., Badr, H., Daly, S., Negahi Shirazi, A., & Dehghani, F. (2016) · Polymers · doi:10.3390/polym8010020 · Cited by 514
Metadata
- Authors
- Saini, M.
- Venue
- World Journal of Clinical Cases
- Publisher
- Baishideng Publishing Group Inc.
- Published
- 2015
- Volume
- 3
- Issue
- 1
- Pages
- 52
- ISSN
- 2307-8960 (ISSN-L)
- OpenAlex
- W2093984144
- Cited by
- 844
- References
- 13
- FWCI
- 47.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.