Pharmacokinetic study of gentamicin-loaded cement in total hip replacements. Comparative effects of varying dosage
The DOI matches its Crossref record.
Abstract
A randomised, double-blind study was performed in two groups of 15 patients undergoing total hip replacements, using antibiotic-loaded acrylic cement containing 0.5 g and 1.0 g gentamicin base respectively per 40 g pack of powdered polymer. Postoperatively, the gentamicin levels in the blood, in the urine and in the wound drainage fluid were measured. In both groups of patients, the serum gentamicin concentrations were low whereas the wound drainage fluid contained highly effective antibacterial concentrations. Serum, urine and wound secretion levels showed approximately two-fold higher concentrations in the group of patients receiving the higher gentamicin load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of polymethylmethacrylate bone cement in modern orthopaedic surgery
Webb, J. C. J., & Spencer, R. F. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b7.19148 · Cited by 386
Tan, H., Ma, R., Lin, C., Liu, Z., & Tang, T. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms14011854 · Cited by 373
Long-term elution of antibiotics from bone-cement
Masri, B. A., Duncan, C. P., & Beauchamp, C. P. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90179-6 · Cited by 356
Elution characteristics of vancomycin and tobramycin combined in acrylic bone—cement
Penner, M. J., Masri, B. A., & Duncan, C. P. (1996) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(96)80135-5 · Cited by 324
Backgrounds of antibiotic-loaded bone cement and prosthesis-related infection
Hendriks, J. G. E., van Horn, J. R., van der Mei, H. C., & Busscher, H. J. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00554-4 · Cited by 291
“Rinsing the operative area with antibiotic containing solutions only resulted in adequate concentrations for less than 24 h [129], where antibioticloaded bone cements achieve these for a few days [129,131,132].”
Background
Metadata
- Authors
- Wahlig, H., Dingeldein, E., Buchholz, H., Buchholz, M., & Bachmann, F.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1984-03
- Volume
- 66-B
- Issue
- 2
- Pages
- 175-179
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2296689601
- Cited by
- 145
- References
- 0
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pharmacokinetic study of gentamicin-loaded cement in total hip replacements. Comparative effects of varying dosage. https://app.cochat.ai/papers/10.1302/0301-620x.66b2.6707051
- The paper
- Wahlig, H., Dingeldein, E., Buchholz, H., Buchholz, M., & Bachmann, F. (1984). Pharmacokinetic study of gentamicin-loaded cement in total hip replacements. Comparative effects of varying dosage. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.66b2.6707051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.