CoChat

Pharmacokinetic study of gentamicin-loaded cement in total hip replacements. Comparative effects of varying dosage

Wahlig, H, Dingeldein, E, Buchholz, HW, Buchholz, M, Bachmann, F · 1984 · The Journal of Bone and Joint Surgery. British volume
Cited by 145

The DOI matches its Crossref record.

Abstract

A randomised, double-blind study was performed in two groups of 15 patients undergoing total hip replacements, using antibiotic-loaded acrylic cement containing 0.5 g and 1.0 g gentamicin base respectively per 40 g pack of powdered polymer. Postoperatively, the gentamicin levels in the blood, in the urine and in the wound drainage fluid were measured. In both groups of patients, the serum gentamicin concentrations were low whereas the wound drainage fluid contained highly effective antibacterial concentrations. Serum, urine and wound secretion levels showed approximately two-fold higher concentrations in the group of patients receiving the higher gentamicin load.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1302/0301-620x.66b2.6707051

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 145

Metadata

Authors
Wahlig, H., Dingeldein, E., Buchholz, H., Buchholz, M., & Bachmann, F.
Venue
The Journal of Bone and Joint Surgery. British volume
Published
1984-03
Volume
66-B
Issue
2
Pages
175-179
ISSN
  • 0301-620X (ISSN-L)
  • 2044-5377
OpenAlex
W2296689601
Cited by
145
References
0
FWCI
4.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pharmacokinetic study of gentamicin-loaded cement in total hip replacements. Comparative effects of varying dosage. https://app.cochat.ai/papers/10.1302/0301-620x.66b2.6707051
The paper
Wahlig, H., Dingeldein, E., Buchholz, H., Buchholz, M., & Bachmann, F. (1984). Pharmacokinetic study of gentamicin-loaded cement in total hip replacements. Comparative effects of varying dosage. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.66b2.6707051

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.