The axis of rotation of the ankle joint
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The axis of the talo-crural joint was analysed by roentgen stereophotogrammetry in eight healthy volunteers. Examinations were performed at 10 degrees increments of flexion and pronation/supination of the foot as well as medial and lateral rotation of the leg. Results indicate that the talo-crural joint axis changes continuously throughout the range of movement. In dorsiflexion it tended to be oblique downward and laterally. In rotation of the leg, the axis took varying inclinations between horizontal and vertical. All axes in each subject lay close to the midpoint of a line between the tips of the malleoli. Our study indicates that the talo-crural joint axis may alter considerably during the arc of motion and differ significantly between individuals. This prompts caution in the use of hinge axes in orthoses and prostheses for the ankle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some Applications of the Functional Anatomy of the Ankle Joint
Close, J. R. (1956) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-195638040-00005 · Cited by 452
Barnett, C. H., & Napier, J. R. (1952) · PubMed · Cited by 291
Rotatory stability of the load-bearing ankle. An experimental study
McCullough, C., & Burge, P. (1980) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.62b4.7430225 · Cited by 169
A Roentgen Stereophotogrammetric System: Construction, Calibration and Technical Accuracy
Selvik, G., Alberius, P., & Aronson, A. S. (1983) · Acta Radiologica Diagnosis · doi:10.1177/028418518302400412 · Cited by 118
Self-citation
Cited by
Brockett, C. L., & Chapman, G. J. (2016) · Orthopaedics and Trauma · doi:10.1016/j.mporth.2016.04.015 · Cited by 597
Morphological muscle and joint parameters for musculoskeletal modelling of the lower extremity
Klein Horsman, M. D., Koopman, H. F. J. M., van der Helm, F. C. T., Prosé, L. P., & Veeger, H. E. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.10.003 · Cited by 445
Validation of a full body 3-D dynamic linked segment model
Kingma, I., de Looze, M. P., Toussaint, H. M., Klijnsma, H. G., & Bruijnen, T. B. M. (1996) · Human Movement Science · doi:10.1016/s0167-9457(96)00034-6 · Cited by 273
A geometric model of the human ankle joint
Leardini, A., O'Connor, J. J., Catani, F., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00022-6 · Cited by 214
In vivo determination of the anatomical axes of the ankle joint complex: An optimization approach
van den Bogert, A. J., Smith, G. D., & Nigg, B. M. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90197-x · Cited by 199
“This requires different methods than in the in oitro studies, because the movements of the talus cannot be measured, except when implanted bone markers are used (Lundberg et al., 1989).”
BackgroundMethod
Metadata
- Authors
- Lundberg, A., Svensson, O., Nemeth, G., & Selvik, G.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1989-01
- Volume
- 71-B
- Issue
- 1
- Pages
- 94-99
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2155529507
- Cited by
- 280
- References
- 4
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.