The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Bone changes in the vascularised fibular graft
Abstract
We report a retrospective review of 62 consecutive patients who had a vascularised fibular transfer to reconstruct a large skeletal defect. We were particularly interested in the bone dynamics of the vascularised graft, since fractures occurred in 25% of the cases at an average time of eight months after surgery. Hypertrophy was more common when the limb was mechanically loaded; it was enhanced where the graft was not bypassed by internal fixation. The length of the graft and the use of additional bone graft material had no influence on the incidence of stress fracture or on hypertrophy. We conclude that a vascularised graft should be protected against fatigue fracture during the first year, and that a gradual increase in mechanical loading will enhance remodelling and hypertrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Autogenous cortical bone grafts in the reconstruction of segmental skeletal defects.
Enneking, W. F., Eady, J. L., & Burchardt, H. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062070-00001 · Cited by 430
The effect of prolonged physical training on the properties of long bone: a study of Wolff's Law.
Woo, S. L., Kuei, S. C., Amiel, D., Gomez, M. A., Hayes, W. C., White, F. C., & Akeson, W. H. (1981) · PubMed · Cited by 421
Functional adaptation of bone to increased stress. An experimental study.
Goodship, A. E., Lanyon, L. E., & McFie, H. (1979) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197961040-00008 · Cited by 416
Tonino, A., Davidson, C., Klopper, P., & Linclau, L. (1976) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.58b1.1270486 · Cited by 338
Current Concepts of Bone Formation
Bassett, C. A. L. (1962) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196244060-00020 · Cited by 259
Mechanical function as an influence on the structure and form of bone
Lanyon, L., & Baggott, D. (1976) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.58b4.1018029 · Cited by 200
Vascularized bone autografts. Experience with 41 cases.
Weiland, A. J., Moore, J., & Daniel, R. K. (1983) · PubMed · Cited by 190
Mnaymneh, W. A., Malinin, T. I., Makley, J. T., & Dick, H. M. (1985) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198507000-00009 · Cited by 99
Microcracking in dog bone under load: A biomechanical study of bone visco-elasticity
Jonsson, U., & Eriksson, K. (1984) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678408992391 · Cited by 24
Cited by
Pelissier, P. H., Masquelet, A. C., Bareille, R., Pelissier, S. M., & Amedee, J. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00165-7 · Cited by 613
Treatment of critical-sized bone defects: clinical and tissue engineering perspectives
Roddy, E., DeBaun, M. R., Daoud-Gray, A., Yang, Y. P., & Gardner, M. J. (2018) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-017-2063-0 · Cited by 459
Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering
Brydone, A. S., Meek, D., & Maclaine, S. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim770 · Cited by 456
Osteonal Microcracking Pattern: A Potential Vitality Marker in Human Bone Trauma
Schwab, N., Galtés, I., Winter-Buchwalder, M., Ortega-Sánchez, M., & Jordana, X. (2023) · Biology · doi:10.3390/biology12030399 · Cited by 8
Metadata
- Authors
- de Boer, H., & Wood, M.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1989-05
- Volume
- 71-B
- Issue
- 3
- Pages
- 374-378
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2154133182
- Cited by
- 283
- References
- 9
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.