The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Six-year results of hydroxyapatite-coated total hip replacement
Abstract
We present the 5.6- to 7.6-year results of our first 118 hydroxyapatite (HA)-coated total hip replacements in patients under 66 years of age. The titanium femoral component has proximal HA coating and was usually articulated with an HA-coated threaded cup. The HA coating of 50 microns thickness has a porosity of below 3%, 97% HA purity and 65% crystallinity. The survival rate at a mean of six years was 100% for the HA-coated stems and 99% for the HA-threaded cups. The average Harris hip score at one year was 96, and at three years and thereafter 98. There was a very low incidence of early pain after surgery. Serial radiographs showed rapid bony integration of implants with evidence of bone apposition on the coating within six months. By Engh's criteria, all the femoral components had confirmed bone ongrowth after three years. We found no deterioration of results with time, and consider that our clinical and radiological results show that HA coatings can provide early pain relief and durable implant fixation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
“Modes of Failure” of Cemented Stem-Type Femoral Components: A Radiographic Analysis of Loosening
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_8 · Cited by 3,399
Ectopic Ossification Following Total Hip Replacement: Incidence and a Method of Classification
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_25 · Cited by 2,537
Radiological Demarcation of Cemented Sockets in Total Hip Replacement
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_9 · Cited by 2,516
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS
DʼAubigné, R. M., & Postel, M. (1954) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-195436030-00001 · Cited by 1,653
Bonding of bone to apatite-coated implants
Geesink, R., de Groot, K., & Klein, C. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b1.2828374 · Cited by 537
Self-citationSøballe, K., Hansen, E. S., B.‐Rasmussen, H., Jørgensen, P. H., & Bünger, C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100216 · Cited by 506
Bioactive Ceramic Prosthetic Coatings
Ducheyne, P., & Cuckler, J. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199203000-00014 · Cited by 218
Intermittent micromotion inhibits bone ingrowth
Aspenberg, P., Goodman, S. B., Toksvig‐Larsen, S., Ryd, L., & Albrektsson, T. O. (1992) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679209154809 · Cited by 147
Cited by
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Suchanek, W., & Yoshimura, M. (1998) · Journal of Materials Research · doi:10.1557/jmr.1998.0015 · Cited by 2,028
Properties of Osteoconductive Biomaterials: Calcium Phosphates
LeGeros, R. Z. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200202000-00009 · Cited by 1,987
Understanding and controlling the bone–implant interface
Puleo, D. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00160-x · Cited by 1,342
Material fundamentals and clinical performance of plasma‐sprayed hydroxyapatite coatings: A review
Sun, L., Berndt, C. C., Gross, K. A., & Kucuk, A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1056 · Cited by 1,065
Metadata
- Authors
- Geesink, R., & Hoefnagels, N.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1995-07
- Volume
- 77-B
- Issue
- 4
- Pages
- 534-547
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2162504688
- Cited by
- 327
- References
- 8
- FWCI
- 17.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Six-year results of hydroxyapatite-coated total hip replacement. https://app.cochat.ai/papers/10.1302/0301-620x.77b4.7615595
- The paper
- Geesink, R., & Hoefnagels, N. (1995). Six-year results of hydroxyapatite-coated total hip replacement. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.77b4.7615595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.