Computer-assisted total knee replacement: A CONTROLLED CADAVER STUDY USING A MULTI-PARAMETER QUANTITATIVE CT ASSESSMENT OF ALIGNMENT (THE PERTH CT PROTOCOL)
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A controlled study, comparing computer- and conventional jig-assisted total knee replacement in six cadavers is presented. In order to provide a quantitative assessment of the alignment of the replacements, a CT-based technique which measures seven parameters of alignment has been devised and used. In this a multi-slice CT machine scanned in 2.5 mm slices from the acetabular roof to the dome of the talus with the subject’s legs held in a standard position. The mechanical and anatomical axes were identified, from three-dimensional landmarks, in both anteroposterior and lateral planes. The coronal and sagittal alignment of the prosthesis was then measured against the axes. The rotation of the femoral component was measured relative to the transepicondylar axis. The rotation of the tibial component was measured with reference to the posterior tibial condyles and the tibial tuberosity. Coupled femorotibial rotational alignment was assessed by superimposition of the femoral and tibial axial images. The radiation dose was 2.7 mSV. The computer-assisted total knee replacements showed better alignment in rotation and flexion of the femoral component, the posterior slope of the tibial component and in the matching of the femoral and tibial components in rotation. Differences were statistically significant and of a magnitude that support extension of computer assistance to the clinical situation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Berger, R. A., Rubash, H. E., Seel, M. J., THOMPSON, W. H., & Crossett, L. S. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199301000-00008 · Cited by 901
Heegaard, J. H., Leyvraz, P., & Hovey, C. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00020-1 · Cited by 78
Cited by
Choong, P. F., Dowsey, M. M., & Stoney, J. D. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.02.018 · Cited by 447
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans
Biswas, D., Bible, J. E., Bohan, M., Simpson, A. K., Whang, P. G., & Grauer, J. N. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.h.01199 · Cited by 441
Good Alignment After Total Knee Arthroplasty Leads to Faster Rehabilitation and Better Function
Longstaff, L. M., Sloan, K., Stamp, N., Scaddan, M., & Beaver, R. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.03.002 · Cited by 380
Kim, Y.-H., Park, J.-W., Kim, J.-S., & Park, S.-D. (2014) · International Orthopaedics · doi:10.1007/s00264-013-2097-9 · Cited by 367
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Metadata
- Authors
- Chauhan, S. K., Clark, G. W., Lloyd, S., Scott, R. G., Breidahl, W., & Sikorski, J. M.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2004-08
- Volume
- 86-B
- Issue
- 6
- Pages
- 818-823
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W1938954276
- Cited by
- 272
- References
- 3
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.