The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Interbody fusion with allograft and rhBMP-2 leads to consistent fusion but early subsidence
Open accessAbstract
We carried out a prospective study to determine whether the addition of a recombinant human bone morphogenetic protein (rhBMP-2) to a machined allograft spacer would improve the rate of intervertebral body fusion in the spine. We studied 77 patients who were to undergo an interbody fusion with allograft and instrumentation. The first 36 patients received allograft with adjuvant rhBMP-2 (allograft/rhBMP-2 group), and the next 41, allograft and demineralised bone matrix (allograft/demineralised bone matrix group). Each patient was assessed clinically and radiologically both pre-operatively and at each follow-up visit using standard methods. Follow-up continued for two years. Every patient in the allograft/rhBMP-2 group had fused by six months. However, early graft lucency and significant (> 10%) subsidence were seen radiologically in 27 of 55 levels in this group. The mean graft height subsidence was 27% (13% to 42%) for anterior lumbar interbody fusion, 24% (13% to 40%) for transforaminal lumbar interbody fusion, and 53% (40% to 58%) for anterior cervical discectomy and fusion. Those who had undergone fusion using allograft and demineralised bone matrix lost only a mean of 4.6% (0% to 15%) of their graft height. Although a high rate of fusion (100%) was achieved with rhBMP-2, significant subsidence occurred in more than half of the levels (23 of 37) in the lumbar spine and 33% (6 of 18) in the cervical spine. A 98% fusion rate (62 of 63 levels) was achieved without rhBMP-2 and without the associated graft subsidence. Consequently, we no longer use rhBMP-2 with allograft in our practice if the allograft has to provide significant structural support.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oswestry Low Back Pain Disability Questionnaire
Fairbank, J. C. T., Couper, J., Davies, J. B., & O'Brien, J. P. (2020) · PsycTESTS Dataset · doi:10.1037/t04205-000 · Cited by 2,033
Cited by
Carragee, E. J., Hurwitz, E. L., & Weiner, B. K. (2011) · The Spine Journal · doi:10.1016/j.spinee.2011.04.023 · Cited by 1,395
A Review of the Clinical Side Effects of Bone Morphogenetic Protein-2
James, A. W., LaChaud, G., Shen, J., Asatrian, G., Nguyen, V., Zhang, X., Ting, K., & Soo, C. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0357 · Cited by 1,131
Zara, J. N., Siu, R. K., Zhang, X., Shen, J., Ngo, R., Lee, M., Li, W., Chiang, M., Chung, J., Kwak, J., et al. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0555 · Cited by 560
Fu, R., Selph, S., McDonagh, M., Peterson, K., Tiwari, A., Chou, R., & Helfand, M. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-12-201306180-00006 · Cited by 446
Complications with the use of bone morphogenetic protein 2 (BMP-2) in spine surgery
Tannoury, C. A., & An, H. S. (2014) · The Spine Journal · doi:10.1016/j.spinee.2013.08.060 · Cited by 433
Metadata
- Authors
- Vaidya, R., Weir, R., Sethi, A., Meisterling, S., Hakeos, W., & Wybo, C. D.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2007-03
- Volume
- 89-B
- Issue
- 3
- Pages
- 342-345
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2140102422
- Cited by
- 172
- References
- 1
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interbody fusion with allograft and rhBMP-2 leads to consistent fusion but early subsidence. https://app.cochat.ai/papers/10.1302/0301-620x.89b3.18270
- The paper
- Vaidya, R., Weir, R., Sethi, A., Meisterling, S., Hakeos, W., & Wybo, C. D. (2007). Interbody fusion with allograft and rhBMP-2 leads to consistent fusion but early subsidence. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.89b3.18270
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.