The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Internal rotational error of the tibial component is a major cause of pain after total knee replacement
Open accessAbstract
This study used CT analysis to determine the rotational alignment of 39 painful and 26 painless fixed-bearing total knee replacements (TKRs) from a cohort of 740 NexGen Legacy posterior-stabilised and cruciate-retaining prostheses implanted between May 1996 and August 2003. The mean rotation of the tibial component was 4.3° of internal rotation (25.4° internal to 13.9° external rotation) in the painful group and 2.2° of external rotation (8.5° internal to 18.2° external rotation) in the painfree group (p = 0.024). In the painful group 17 tibial components were internally rotated more than 9° compared with none in the painfree group (p < 0.001). Additionally, six femoral components in the painful group were internally rotated more than 6° compared with none in the painfree group (p = 0.017). External rotational errors were not found to be associated with pain. Overall, 22 (56.4%) of the painful TKRs had internal rotational errors involving the femoral, the tibial or both components. It is estimated that at least 4.6% of all our TKRs have been implanted with significant internal rotational errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rationale, of The Knee Society Clinical Rating System
INSALL, J. N., DORR, L. D., SCOTT, R. D., & NORMAN, W. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198911000-00004 · Cited by 4,793
Baker, P. N., van der Meulen, J. H., Lewsey, J., & Gregg, P. J. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b7.19091 · Cited by 975
HAWKER, G., WRIGHT, J., COYTE, P., PAUL, J., DITTUS, R., CROXFORD, R., KATZ, B., BOMBARDIER, C., HECK, D., & FREUND, D. (1998) · The Journal of Bone and Joint Surgery (American Volume) · doi:10.2106/00004623-199802000-00003 · Cited by 682
Robertsson, O., Dunbar, M., Pehrsson, T., Knutson, K., & Lidgren, L. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317411852 · Cited by 674
Ranawat Award Paper: Predicting Total Knee Replacement Pain: A Prospective, Observational Study
Brander, V. A., Stulberg, S. D., Adams, A. D., Harden, R. N., Bruehl, S., Stanos, S. P., & Houle, T. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000092983.12414.e9 · Cited by 599
Kim, Y., Kim, J.-S., Choi, Y., & Kwon, O. (2009) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01700 · Cited by 138
The management of patients with painful total knee replacement
Toms, A. D., Mandalia, V., Haigh, R. C., & Hopwood, B. (2009) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.91b2.20995 · Cited by 131
Patient-reported outcomes after fixed- versus mobile-bearing total knee replacement
Wylde, V., Learmonth, I. D., Potter, A., Bettinson, K., & Lingard, E. A. (2008) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.90b9.21031 · Cited by 121
Oh, K.-J., Pandher, D. S., Lee, S. H., Joon, S. D. S., & Lee, S. T. (2008) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.06.002 · Cited by 68
Cited by
Predictors of persistent pain after total knee arthroplasty: a systematic review and meta-analysis
Lewis, G. N., Rice, D. A., McNair, P. J., & Kluger, M. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu441 · Cited by 587
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Metadata
- Authors
- Nicoll, D., & Rowley, D. I.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2010-09
- Volume
- 92-B
- Issue
- 9
- Pages
- 1238-1244
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2116323295
- Cited by
- 314
- References
- 9
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.