X-Ray Determination of Calcite-Dolomite: an Evaluation
The DOI matches its Crossref record.
Abstract
The observation that X-ray methods currently in use for determination of calcite and dolomite in rocks and sediments often give inconsistent results led us to structure an experiment to evaluate their relative accuracy. Three dolomite standards were selected from which 33 mixtures (11 each) of calcite and dolomite were prepared in triplicate (99 total). The intensities of the major calcite and dolomite reflections of each slide were measured by four methods: by fixed-time count on the peak maximum, integral count of a fixed interval across the peak, ruler measurement of peak height and planimeter measurement of peak area. The parameter "dolomite/dolomite plus calcite" was computed for each diffraction pattern. A curve of best-fit and the standard error of this parameter, as a function of weight percent dolomite, were computed for various combinations of individual and average data to determine the relative accuracy of the several types of intensity measures. Results of previous investigators were compared with our data to estimate their relative precision. It is concluded that X-ray peak-height (fixed time) intensity measurement provides the most rapid and precise procedure for determination of calcite and dolomite. Composite data for all types of measurement yield a calibration curve which gives results in terms of weight percent dolomite of about + or -6 at the 95% confidence level. Its true accuracy is probably better. Replicate analysis of unknowns yield mean values with standard deviations of about 3, expressed as percent dolomite. Most of the curves presented by prior investigators compare well with ours; that is, they lie within our documented confidence interval, and data derived from them can probably be considered reliable within the limits of accuracy established by this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gregg, J. M., Bish, D. L., Kaczmarek, S. E., & Machel, H. G. (2015) · Sedimentology · doi:10.1111/sed.12202 · Cited by 480
“Royse et al. (1971) compared these methods and found that they all roughly worked equally well, with the ‘peak-height’ method being the fastest and most precise.”
MethodSchidlowski, M., Eichmann, R., & Junge, C. E. (1975) · Precambrian Research · doi:10.1016/0301-9268(75)90018-2 · Cited by 338
Kaczmarek, S. E., & Sibley, D. F. (2011) · Sedimentary Geology · doi:10.1016/j.sedgeo.2011.07.003 · Cited by 199
“The equation designates a linear relationship between dolomite composition and the position of the dolomite d(104) peak (Royce et al., 1971).”
BackgroundDirect physical evidence of dolomite recrystallization
Kaczmarek, S. E., & Sibley, D. F. (2014) · Sedimentology · doi:10.1111/sed.12119 · Cited by 131
Kaczmarek, S. E., & Thornton, B. P. (2017) · Chemical Geology · doi:10.1016/j.chemgeo.2017.08.004 · Cited by 128
Metadata
- Authors
- C. F. Royse, Jr.
- Venue
- SEPM Journal of Sedimentary Research
- Publisher
- Society for Sedimentary Geology
- Published
- 1971
- Volume
- Vol. 41
- Issue
- 2
- Pages
- 483-488
- ISSN
- 0022-4472 (ISSN-L)
- 1527-1404
- OpenAlex
- W2128022947
- Cited by
- 55
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-Ray Determination of Calcite-Dolomite: an Evaluation. https://app.cochat.ai/papers/10.1306/74d722a7-2b21-11d7-8648000102c1865d
- The paper
- C. F. Royse, Jr. (1971). X-Ray Determination of Calcite-Dolomite: an Evaluation. SEPM Journal of Sedimentary Research. https://doi.org/10.1306/74d722a7-2b21-11d7-8648000102c1865d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.