CoChat

Quantification of Serum 25-Hydroxyvitamin D 2 and D 3 Using HPLC-Tandem Mass Spectrometry and Examination of Reference Intervals for Diagnosis of Vitamin D Deficiency

Amy K. Saenger, Thomas J. Laha, Deborah E. Bremner, S.M. Hossein Sadrzadeh · 2005 · American Journal of Clinical Pathology
Cited by 146

The DOI matches its OpenAlex record.

Abstract

Serum levels of 25-hydroxyvitamin D are important in establishing true vitamin D levels in humans. The purposes of this study were to develop a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection of 25-hydroxyvitamin D(2) and D(3) and establish reference intervals for these analytes. Chromatographic separation of 25(OH)D(2) and 25(OH)D(3) was achieved after adding deuterated Delta(9)-tetrahydrocannabinol (D(9)-THC-D(3)) and organic extraction. The 3 ions were ionized using positive electrospray ionization and detected in the multiple-reaction monitoring mode using mass (m)/charge (z) transitions of 318.15 > 196.20 (Delta(9)-THC-D(3)), 401.15 > 365.2 (25(OH)D(3)), and 413.15 > 355.20 (25(OH)D(2)). Reference interval study results were compared with current 25(OH)D recommendations. Elution of 25(OH)D(2), 25(OH)D(3), and Delta(9)-THC-D(3) was achieved after 3.0 minutes (total run time, 6.0 minutes). Within- and between-run coefficients of variation were less than 11%. Deming regression of radioimmunoassay and LC-MS/MS methods for total 25(OH)D levels yielded a slope of 0.97 (95% confidence interval, 0.88-1.05) and y-intercept of -1.74 ng/mL. Reference intervals were less than recommended levels (D(2), 0.0-12.1; D(3), 5.5-41.4; total vitamin D, 6.0-43.5 ng/mL [0-30, 14-103, 15-109 nmol/L, respectively]) with no statistically significant differences in race, age, or sex. This LC-MS/MS method provides a rapid, accurate, sensitive, and cost-effective alternative to other methods for detection of 25(OH)D(2) and 25(OH)D(3) at nanomolar concentrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1309/j32u-f7gt-qpwn-25ap

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 146

Metadata

Authors
Saenger, A. K., Laha, T. J., Bremner, D. E., & Sadrzadeh, S. M. H.
Venue
American Journal of Clinical Pathology
Publisher
Oxford University Press
Published
2005-06-01
Volume
125
Issue
6
Pages
914-920
ISSN
0002-9173 (ISSN-L)
OpenAlex
W2157343211
Cited by
146
References
0
FWCI
2.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Serum 25-Hydroxyvitamin D 2 and D 3 Using HPLC-Tandem Mass Spectrometry and Examination of Reference Intervals for Diagnosis of Vitamin D Deficiency. https://app.cochat.ai/papers/10.1309/j32u-f7gt-qpwn-25ap
The paper
Saenger, A. K., Laha, T. J., Bremner, D. E., & Sadrzadeh, S. M. H. (2005). Quantification of Serum 25-Hydroxyvitamin D 2 and D 3 Using HPLC-Tandem Mass Spectrometry and Examination of Reference Intervals for Diagnosis of Vitamin D Deficiency. American Journal of Clinical Pathology. https://doi.org/10.1309/j32u-f7gt-qpwn-25ap

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.