The DOI matches its Crossref record.
A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular Polysaccharides
Open accessAbstract
We developed a multiplexed indirect immunofluorescent assay for antibodies to pneumococcal polysaccharides (PnPs) based on the Luminex multiple analyte profiling system (Luminex, Austin, TX). The assay simultaneously determines serum IgG concentrations to 14 PnPs serotypes: 1, 3, 4, 5, 6B, 7F, 8, 9N, 9V, 12F; 14, 18C, 19F, and 23F. To assess the specificity of the multiplexed assay for each individual serotype, inhibition-of-binding studies were conducted using adult serum samples obtained after pneumococcal vaccination. Except for the closely related serotypes 9V and 9N, we demonstrated inhibition by homologous serotypes of more than 95% and inhibition by heterologous serotypes of less than 15% for all 14 PnPs serotypes. There was, however, high heterologous inhibition of 50% or greater with some serotypes. These cross-reacting antibodies could not be removed by preabsorption with pneumococcal C-polysaccharide but were removed by additional preabsorption with serotype 22F polysaccharide. The multiplexed Luminex assay showed good overall agreement with a well-established enzyme-linked immunosorbent assay that is currently recommended for evaluation of pneumococcal vaccine immunogenicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
de Jager, W., te Velthuis, H., Prakken, B. J., Kuis, W., & Rijkers, G. T. (2003) · Clinical and Vaccine Immunology · doi:10.1128/cdli.10.1.133-139.2003 · Cited by 568
duPont, N. C., Wang, K., Wadhwa, P. D., Culhane, J. F., & Nelson, E. L. (2005) · Journal of Reproductive Immunology · doi:10.1016/j.jri.2005.03.005 · Cited by 318
Multiplexed microsphere-based flow cytometric assays
Kellar, K. L., & Iannone, M. A. (2002) · Experimental Hematology · doi:10.1016/s0301-472x(02)00922-0 · Cited by 282
Opalka, D., Lachman, C. E., MacMullen, S. A., Jansen, K. U., Smith, J. F., Chirmule, N., & Esser, M. T. (2003) · Clinical and Vaccine Immunology · doi:10.1128/cdli.10.1.108-115.2003 · Cited by 276
High-throughput fluorescent multiplex array for indoor allergen exposure assessment
Earle, C. D., King, E. M., Tsay, A., Pittman, K., Saric, B., Vailes, L., Godbout, R., Oliver, K. G., & Chapman, M. D. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2006.11.004 · Cited by 98
Metadata
- Authors
- Pickering, J. W., Martins, T. B., Greer, R. W., Schroder, M. C., Astill, M. E., Litwin, C. M., Hildreth, S. W., & Hill, H. R.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-04
- Volume
- 117
- Issue
- 4
- Pages
- 589-596
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2150219782
- Cited by
- 177
- References
- 0
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular Polysaccharides. https://app.cochat.ai/papers/10.1309/lmch-c4q2-vfl9-3t1a
- The paper
- Pickering, J. W., Martins, T. B., Greer, R. W., Schroder, M. C., Astill, M. E., Litwin, C. M., Hildreth, S. W., & Hill, H. R. (2002). A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular Polysaccharides. American Journal of Clinical Pathology. https://doi.org/10.1309/lmch-c4q2-vfl9-3t1a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.