CoChat

Initial Outcomes from a Multicenter Study Utilizing the Indego Powered Exoskeleton in Spinal Cord Injury

Open access
Tefertiller, Candy, Hays, Kaitlin, Jones, Janell, Jayaraman, Arun, Hartigan, Clare, Bushnik, Tamara, Forrest, Gail F. · 2018 · Topics in Spinal Cord Injury Rehabilitation
Cited by 165

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: To assess safety and mobility outcomes utilizing the Indego powered exoskeleton in indoor and outdoor walking conditions with individuals previously diagnosed with a spinal cord injury (SCI). Methods: We conducted a multicenter prospective observational cohort study in outpatient clinics associated with 5 rehabilitation hospitals. A convenience sample of nonambulatory individuals with SCI (N = 32) completed an 8-week training protocol consisting of walking training 3 times per week utilizing the Indego powered exoskeleton in indoor and outdoor conditions. Participants were also trained in donning/doffing the exoskeleton during each session. Safety measures such as adverse events (AEs) were monitored and reported. Time and independence with donning/doffing the exoskeleton as well as walking outcomes to include the 10-meter walk test (10MWT), 6-minute walk test (6MWT), Timed Up & Go test (TUG), and 600-meter walk test were evaluated from midpoint to final evaluations. Results: All 32 participants completed the training protocol with limited device-related AEs, which resulted in no interruption in training. The majority of participants in this trial were able to don and doff the Indego independently. Final walking speed ranged from 0.19 to 0.55 m/s. Final average indoor and outdoor walking speeds among all participants were 0.37 m/s (SD = 0.08, 0.09, respectively), after 8 weeks of training. Significant (p < .05) improvements were noted between midpoint and final gait speeds in both indoor and outdoor conditions. Average walking endurance also improved among participants after training. Conclusion: The Indego was shown to be safe for providing upright mobility to 32 individuals with SCIs who were nonambulatory. Improvements in speed and independence were noted with walking in indoor and outdoor conditions as well as with donning/doffing the exoskeleton.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1310/sci17-00014

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 165

Metadata

Authors
Tefertiller, C., Hays, K., Jones, J., Jayaraman, A., Hartigan, C., Bushnik, T., & Forrest, G. F.
Venue
Topics in Spinal Cord Injury Rehabilitation
Published
2018-01
Volume
24
Issue
1
Pages
78-85
ISSN
1082-0744 (ISSN-L)
OpenAlex
W2770897917
Cited by
165
References
2
FWCI
4.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.