Comparison of Two Point-of-Care Lipid Analyzers for Use in Global Cardiovascular Risk Assessments
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Point-of-care (POC) lipid testing is increasingly used in community-and office-based practice. Two analyzers commonly used in the US are CardioChek PA and Cholostech LDX. Both directly measure total cholesterol (TC) and high-density lipoprotein cholesterol (HDL-C), mandatory values in calculating a Framingham Risk Score (FRS). The FRS in turn informs the clinician of the need for lipid-modifying therapy and the degree of therapeutic intensity. Objective: To compare the performance of CardioChek PA and Cholestech LDX. Methods: Staff members from the Colorado Prevention Center were included in the study, with all having fasted for 12 hours beforo the testing. No medical history was obtained. A venous blood sample was collected for lipid measurements conducted in a laboratory, and 2 finger sticks were obtained at that time and analyzed immediately on-site using the POC analyzers. Intraclass correlation coefficients (ICCs) were determined for each analyzer versus the laboratory analysis, with values greater than 0.75 defined as Indicators of excellent reproducibility. We then assessed how interanalyzer differences in TC or HDL-C impacted the FRS lipid categorization. Results: Thirty-four adults (aged 24-56 y) participated in the study. The ICC between Cholestech LDX and the laboratory standard exceeded 075 for all 4 lipid categories (TC, p = 0.96; HDL-C, p = 0.88; low-density lipoprotein cholesterol, ρ = 0.87; triglycerides, ρ = 0.99). By contrast, the only ICC exceeding 0.75 using CardioChek PA was for triglycerides (ρ = 0.84). When applied in calculating the FRS, the Cholestech LDX analyzer misclassified fewer individuals for TC versus the CardioChek PA analyzer (5 vs 21). Overall, Cholestech LDX provided TC and HDL-C values in the correct FRS category more frequently versus CardioChek PA (TC, p < 0.001; HDL-C, p > 0.001). Limitations of the study include use of only 2 POC products and small sample size with no known risk factors. This project does not prove superior accuracy of either device, but reflects a real-world comparison of the analyzers conducted at a single center. Conclusions: The Cholestech LDX analyzer demonstrated better reproducibility than the CardioChek PA analyzer when compared with laboratory gold standard analysis and allowed more accurate categorization for FRS. Since results obtained from these analyzers have the potential to impact treatment decisions, larger, prospective, comparative studies seem warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grundy, S. M., Cleeman, J. I., Merz, C. N. B., Brewer, H. B., Clark, L. T., Hunninghake, D. B., Pasternak, R. C., Smith, S. C., & Stone, N. J. (2004) · Circulation · doi:10.1161/01.cir.0000133317.49796.0e · Cited by 6,902
Explaining the decrease in U.S. deaths from coronary disease, 1980–2000
Ford, E. S., Ajani, U. A., Croft, J. B., Critchley, J. A., Labarthe, D. R., Kottke, T. E., Giles, W. H., & Capewell, S. (2007) · New England Journal of Medicine · doi:10.1056/nejmsa053935 · Cited by 2,757
Cited by
Willard-Grace, R., Chen, E. H., Hessler, D., DeVore, D., Prado, C., Bodenheimer, T., & Thom, D. H. (2015) · The Annals of Family Medicine · doi:10.1370/afm.1768 · Cited by 143
Krantz, M. J., Coronel, S. M., Whitley, E. M., Dale, R., Yost, J., & Estacio, R. O. (2013) · American Journal of Public Health · doi:10.2105/ajph.2012.301068 · Cited by 99
Self-citationEffect of the Site of Measurement of Waist Circumference on the Prevalence of the Metabolic Syndrome
Mason, C., & Katzmarzyk, P. T. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.02.018 · Cited by 65
Kinsey, A. W., Eddy, W. R., Madzima, T. A., Panton, L. B., Arciero, P. J., Kim, J.-S., & Ormsbee, M. J. (2014) · British Journal of Nutrition · doi:10.1017/s0007114514001068 · Cited by 38
Metadata
- Authors
- Dale, R. A., Jensen, L. H., & Krantz, M. J.
- Venue
- Annals of Pharmacotherapy
- Publisher
- SAGE Publications
- Published
- 2008-04-15
- Volume
- 42
- Issue
- 5
- Pages
- 633-639
- ISSN
- 0012-6578 (ISSN-L)
- 1060-0280
- 1542-6270
- OpenAlex
- W2122184749
- Cited by
- 83
- References
- 2
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.