The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Hydrolyzing metal salts as coagulants
Open accessAbstract
Aluminium and ferric salts are widely used as coagulants in water and wastewater treatment. They are effective in removing a broad range of impurities from water, including colloidal particles and dissolved organic substances. Their mode of action is broadly understood in terms of essentially two mechanisms: charge neutralization of negatively charged colloids by cationic hydrolysis products and incorporation of impurities in an amorphous precipitate of metal hydroxide. The relative importance of these two mechanisms depends on many factors, especially pH and coagulant dosage. Alternative coagulants based on prehydrolyzed forms of aluminium or iron can be more effective than the traditional materials in many cases, but their mode of action is not completely understood, especially with regard to the role of charge neutralization and hydroxide precipitation. Basic principles of colloid stability and metal ion hydrolysis are briefly reviewed, and the action of hydrolyzing metal coagulants is then discussed, with some examples from recent experimental studies. Although it is possible to interpret results reasonably well in terms of established ideas, there are still some uncertainties that need to be resolved
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Intermolecular and Surface Forces
(2011) · Elsevier eBooks · doi:10.1016/c2011-0-05119-0 · Cited by 8,968
Chemical Water and Wastewater Treatment VIII
Hahn, H., Hoffman, E., & Odegaard, H. (2015) · Water Intelligence Online · doi:10.2166/9781780402840 · Cited by 320
Aqueous-Environmental Chemistry of Metals
(1975) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/58.6.1308 · Cited by 208
Chemical Water and Wastewater Treatment IV
Hahn, H. H., Hoffmann, E., & Ødegaard, H. (1996) · Springer eBooks · doi:10.1007/978-3-642-61196-4 · Cited by 43
Cited by
Martínez-Huitle, C. A., & Brillas, E. (2009) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2008.09.017 · Cited by 2,250
Brillas, E., & Martínez-Huitle, C. A. (2015) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.11.016 · Cited by 2,009
Sirés, I., & Brillas, E. (2012) · Environment International · doi:10.1016/j.envint.2011.07.012 · Cited by 1,008
Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review
Sillanpää, M., Ncibi, M. C., Matilainen, A., & Vepsäläinen, M. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2017.09.113 · Cited by 768
Garcia-Segura, S., Eiband, M. M. S. G., de Melo, J. V., & Martínez-Huitle, C. A. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.07.047 · Cited by 740
Metadata
- Authors
- Gregory, J., & Duan, J.
- Venue
- Pure and Applied Chemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2001-01-01
- Volume
- 73
- Issue
- 12
- Pages
- 2017-2026
- ISSN
- 0033-4545 (ISSN-L)
- 1365-3075
- OpenAlex
- W2106082257
- Cited by
- 316
- References
- 5
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.