CoChat

Cortical Bone in the Human Femoral Neck: Three-Dimensional Appearance and Porosity Using Synchrotron Radiation

Open access
Bousson, Valérie, Peyrin, Françoise, Bergot, Catherine, Hausard, Marc, Sautet, Alain, Laredo, Jean-Denis · 2004 · Journal of Bone and Mineral Research
Cited by 179

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A high-resolution CT system using synchrotron radiation allowed visualization of the 3D cortical bone microarchitecture and measurement of intracortical porosity of femoral neck cortical bone specimens from 19 female cadavers imaged at 10.13-μm resolution. 3D reconstruction of specimens showed osteonal system arrangement. Mean porosity was 15.88%. This technique will provide insights into the mechanisms involved in osteoporotic hip fractures. Introduction: The purpose of this study was to show that a high-resolution CT system using synchrotron radiation (SR) allows visualization of the 3D cortical bone microarchitecture of the human femoral neck and quantification of intracortical porosity. Materials and Methods: Bone specimens from the inferior femoral neck were obtained from 19 female cadavers with no hip fracture (mean, 86.9 ± 8.3 years). The specimens, consisting of embedded ∼7 × 7 × 12-mm cortical bone parallelepipeds, were imaged using SR at 10.13-μm resolution. Commercial software was used to visualize both the 660 × 660 × 660-voxel volumes and the 2D axial slices through each volume. Qualitative examination of 2D axial slices focused on the appearance of the vessel canal system, presence of small bright zones (fully mineralized tissue) in the osseous matrix, and presence of cracks. A method was developed to automatically measure 3D intracortical porosity after separating pure bone from pores and cortical bone from trabecular bone. Results and Conclusions: 3D reconstruction of the specimens showed the entire structure and arrangement of the osteonal systems, parallel to the axis of the femoral neck. Bright zones were seen in the outer cortex. No cracks were observed. Porosity values varied widely from 4.96% to 38.87% (mean, 15.88 ± 9.87%). This study establishes that SR microtomography can be used to display the 3D bone microstructure of the human femoral neck cortex and to quantify intracortical porosity. This technique will provide insights into the mechanisms involved in cortical bone loss and osteoporotic hip fractures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.040124

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Metadata

Authors
Bousson, V., Peyrin, F., Bergot, C., Hausard, M., Sautet, A., & Laredo, J.-D.
Venue
Journal of Bone and Mineral Research
Published
2004-05-01
Volume
19
Issue
5
Pages
794-801
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W1976667166
Cited by
179
References
1
FWCI
8.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.