The DOI matches its Crossref record.
Monitoring Skeletal Changes by Radiological Techniques
Abstract
The longitudinal sensitivity of a technique, i.e., its ability to monitor skeletal changes, is affected by two parameters: the long-term precision error (PElt) and the subject group-specific response rate (i.e., annual rates of change). Both need to be considered to avoid misinterpretation of measured changes. A new concept to aid clinical decision making for longitudinal measurements is proposed which is based on three types of measures: criteria for detecting changes—the “least significant change” (LSC) is the smallest change to be considered statistically significant, but for certain clinical questions a smaller margin, the “trend assessment margin” (TAM), can be sufficient for decision making; follow-up time intervals—for follow-up exams the patient should be called in at about the time interval specified by the (population specific) “monitoring time interval” (MTI) or, about one-third of the time earlier, after the “trend assessment interval” (TAI), depending on whether the decision can be based on the LSC or the TAM; and the standard precision error (stdPE)—the smaller stdPE, the more sensitive the technique to monitor skeletal changes. Together, these three measures yield a good characterization of a technique's ability to monitor skeletal changes. Compared with previous concepts, the proposed standardization by a response ratio instead of measures of spread or response rates makes the stdPE substantially less subject group dependent. It allows comparison of stdPE across different studies and could replace the misleading concept of expressing precision as a coefficient of variation. Application of this concept should facilitate the interpretation of measured skeletal changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Papaioannou, A., Morin, S., Cheung, A. M., Atkinson, S., Brown, J. P., Feldman, S., Hanley, D. A., Hodsman, A., Jamal, S. A., Kaiser, S. M., et al. (2010) · Canadian Medical Association Journal · doi:10.1503/cmaj.100771 · Cited by 1,749
Clinical Use of Bone Densitometry: Scientific Review
Cummings, S. R., Bates, D., & Black, D. M. (2002) · JAMA · doi:10.1001/jama.288.15.1889 · Cited by 817
The role of DXA bone density scans in the diagnosis and treatment of osteoporosis
Blake, G. M., & Fogelman, I. (2007) · Postgraduate Medical Journal · doi:10.1136/pgmj.2007.057505 · Cited by 532
Harvey, N. C., Glüer, C. C., Binkley, N., McCloskey, E. V., Brandi, M.-L., Cooper, C., Kendler, D., Lamy, O., Laslop, A., Camargos, B. M., et al. (2015) · Bone · doi:10.1016/j.bone.2015.05.016 · Cited by 486
Self-citationQuantitative computed tomography
Adams, J. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.074 · Cited by 458
Metadata
- Authors
- Glüer, C.-C.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-11-01
- Volume
- 14
- Issue
- 11
- Pages
- 1952-1962
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W1979562073
- Cited by
- 244
- References
- 0
- FWCI
- 11.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring Skeletal Changes by Radiological Techniques. https://app.cochat.ai/papers/10.1359/jbmr.1999.14.11.1952
- The paper
- Glüer, C.-C. (1999). Monitoring Skeletal Changes by Radiological Techniques. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.1999.14.11.1952
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.