Monitoring Skeletal Changes by Radiological Techniques
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The longitudinal sensitivity of a technique, i.e., its ability to monitor skeletal changes, is affected by two parameters: the long-term precision error (PElt) and the subject group-specific response rate (i.e., annual rates of change). Both need to be considered to avoid misinterpretation of measured changes. A new concept to aid clinical decision making for longitudinal measurements is proposed which is based on three types of measures: criteria for detecting changes—the “least significant change” (LSC) is the smallest change to be considered statistically significant, but for certain clinical questions a smaller margin, the “trend assessment margin” (TAM), can be sufficient for decision making; follow-up time intervals—for follow-up exams the patient should be called in at about the time interval specified by the (population specific) “monitoring time interval” (MTI) or, about one-third of the time earlier, after the “trend assessment interval” (TAI), depending on whether the decision can be based on the LSC or the TAM; and the standard precision error (stdPE)—the smaller stdPE, the more sensitive the technique to monitor skeletal changes. Together, these three measures yield a good characterization of a technique's ability to monitor skeletal changes. Compared with previous concepts, the proposed standardization by a response ratio instead of measures of spread or response rates makes the stdPE substantially less subject group dependent. It allows comparison of stdPE across different studies and could replace the misleading concept of expressing precision as a coefficient of variation. Application of this concept should facilitate the interpretation of measured skeletal changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberman, U. A., Weiss, S. R., Bröll, J., Minne, H. W., Quan, H., Bell, N. H., Rodriguez-Portales, J., Downs, R. W., Dequeker, J., Favus, M., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199511303332201 · Cited by 2,288 · cited 1×
“According to published studies, this would be met by ∼60% of the patients on estrogen((12,14)) and ∼80% of the patients on alendronate,((15)) assuming normal distributions of the response.”
Glüer, C. C., Blake, G., Lu, Y., Blunt1, B. A., Jergas1, M., & Genant1, H. K. (1995) · Osteoporosis International · doi:10.1007/bf01774016 · Cited by 1,282
Self-citationNoninvasive assessment of bone mineral and structure: State of the art
Genant, H. K., Engelke, K., Fuerst, T., Glüer, C.-C., Grampp, S., Harris, S. T., Jergas, M., Lang, T., Lu, Y., Majumdar, S., et al. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110602 · Cited by 941 · cited 1×
“The longitudinal sensitivity of a technique, defined as the ability to monitor changes in skeletal status,((1)) is limited by technique imprecision.”
MethodSelf-citationTreatment of Postmenopausal Osteoporosis with Transdermal Estrogen
Lufkin, E. G., Wahner, H. W., O'Fallon, W. M., Hodgson, S. F., Kotowicz, M. A., Lane, A. W., Judd, H. L., Caplan, R. H., & Riggs, B. L. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-1-1 · Cited by 810 · cited 2×
“variable even for an established effective medication like estrogen.((12,13)) By definition, half of the patients will show a response, which is less than the median response, and, consequently, their measured improvement during the MTIT (or TAIT) will be smaller than the LSC (or TAM).”
BackgroundTechnical principles of dual energy X-ray absorptiometry
Blake, G. M., & Fogelman, I. (1997) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(97)80025-6 · Cited by 295 · cited 1×
“If one is, for example, interested in estimating the follow-up time required to establish success of treatment, the power to detect this will depend both on the technique’s imprecision and the true variability over time.((21)) Thus, the SEE can be considered to represent a good approximation of overall diagnostic, bio…”
BackgroundThe effect of percutaneous estradiol and natural progesterone on postmenopausal bone loss
Riis, B. J., Thomsen, K., Strøm, V., & Christianse, C. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(87)90203-1 · Cited by 213 · cited 1×
“variable even for an established effective medication like estrogen.((12,13)) By definition, half of the patients will show a response, which is less than the median response, and, consequently, their measured improvement during the MTIT (or TAIT) will be smaller than the LSC (or TAM).”
BackgroundShould Perimenopausal Women Be Screened for Osteoporosis?
CUMMINGS, S. R., & BLACK, D. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-104-6-817 · Cited by 204
Precision and Discriminatory Ability of Calcaneal Bone Assessment Technologies
Greenspan, S. L., Bouxsein, M. L., Melton, M. E., Kolodny, A. H., Clair, J. H., Delucca, P. T., Stek, M., Faulkner, K. G., & Orwoll, E. S. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.8.1303 · Cited by 191 · cited 1×
“used a similar approach but standardized with the 95% interpercentile range.((8)) Both measures of population spread depend on subject selection criteria and thus are affected by the noted cohort and precision biases.”
MethodDiscrepancies in normative data between Lunar and Hologic DXA systems
Faulkner, K. G., Roberts, L. A., & McClung, M. R. (1996) · Osteoporosis International · doi:10.1007/bf01629574 · Cited by 180
Assessing Reproducibility by the Within-Subject Coefficient of Variation with Random Effects Models
Quan, H., & Shih, W. J. (1996) · Biometrics · doi:10.2307/2532835 · Cited by 152
Appropriate use of bone densitometry.
Genant, H. K., Block, J. E., Steiger, P., Glueer, C. C., Ettinger, B., & Harris, S. T. (1989) · Radiology · doi:10.1148/radiology.170.3.2916037 · Cited by 146
Nguyen, T. V., Sambrook, P. N., & Eisman, J. A. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.124 · Cited by 110 · cited 1×
“) that can only be determined from longitudinal data.((18))”
BackgroundReproducibility of DXA absorptiometry: A model for bone loss estimates
Fuleihan, G. E., Testa, M. A., Angell, J. E., Porrino, N., & LeBoff, M. S. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100704 · Cited by 103 · cited 1×
“Therefore, the reproducibility of techniques has to be based on long-term precision errors, which are usually larger than short-term precision errors.((17)) There are additional error sources (e.”
Background
Cited by
Papaioannou, A., Morin, S., Cheung, A. M., Atkinson, S., Brown, J. P., Feldman, S., Hanley, D. A., Hodsman, A., Jamal, S. A., Kaiser, S. M., et al. (2010) · Canadian Medical Association Journal · doi:10.1503/cmaj.100771 · Cited by 1,749
Clinical Use of Bone Densitometry: Scientific Review
Cummings, S. R., Bates, D., & Black, D. M. (2002) · JAMA · doi:10.1001/jama.288.15.1889 · Cited by 817
The role of DXA bone density scans in the diagnosis and treatment of osteoporosis
Blake, G. M., & Fogelman, I. (2007) · Postgraduate Medical Journal · doi:10.1136/pgmj.2007.057505 · Cited by 532
Harvey, N. C., Glüer, C. C., Binkley, N., McCloskey, E. V., Brandi, M.-L., Cooper, C., Kendler, D., Lamy, O., Laslop, A., Camargos, B. M., et al. (2015) · Bone · doi:10.1016/j.bone.2015.05.016 · Cited by 486
Self-citationQuantitative computed tomography
Adams, J. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.074 · Cited by 458
Metadata
- Authors
- Glüer, C.-C.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-11-01
- Volume
- 14
- Issue
- 11
- Pages
- 1952-1962
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W1979562073
- Cited by
- 244
- References
- 13
- FWCI
- 11.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.