Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 308

The DOI matches its Crossref record.

Variations in Three-Dimensional Cancellous Bone Architecture of the Proximal Femur in Female Hip Fractures and in Controls

Ciarelli, T. E., Fyhrie, D. P., Schaffler, M. B., Goldstein, S. A.·2000·Journal of Bone and Mineral Research

Abstract

Cubes of cancellous bone were obtained from proximal femora of women with hip fractures (n = 26) and from female cadaveric controls (n = 32) to compare architecture and mechanics between groups. Specimens were scanned on a microcomputed tomography system. Stereologic algorithms and model-based estimates were applied to the data to characterize the three-dimensional cancellous microstructure. Cubes were mechanically tested to failure to obtain mechanical properties. Specimens from control subjects had significantly higher bone volume fraction, trabecular number, and connectivity than specimens from patients with hip fractures; no difference in trabecular thickness was observed between groups. Both maximum modulus and ultimate stress were significantly higher in the control than in the fracture group, consistent with the higher bone volume found in the control group. No statistical differences in any of these architectural or mechanical variables were found when groups were matched for bone volume. Specimens from both patients with hip fractures and controls demonstrated strong relationships between trabecular number and bone volume fraction that were statistically equivalent, suggesting that for a given bone mass, both groups have the same overall number of trabeculae. However, there was an architectural difference between fracture and control groups in terms of the three-dimensional spatial arrangement of trabeculae. Fracture specimens had a significantly more anisotropic (oriented) structure than control specimens, with proportionately fewer trabecular elements transverse to the primary load axis, even when matched for bone volume. Relationships between mechanical and architectural parameters were significantly different between groups, suggesting that fracture and control groups have different structure-mechanics relationships, which we hypothesize may be a consequence of the altered three-dimensional structure between groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.2000.15.1.32

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 308

Metadata

Authors
Ciarelli, T. E., Fyhrie, D. P., Schaffler, M. B., & Goldstein, S. A.
Venue
Journal of Bone and Mineral Research
Published
2000-01-01
Volume
15
Issue
1
Pages
32-40
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2091768906
Cited by
308
References
0
FWCI
8.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variations in Three-Dimensional Cancellous Bone Architecture of the Proximal Femur in Female Hip Fractures and in Controls. https://app.cochat.ai/papers/10.1359/jbmr.2000.15.1.32
The paper
Ciarelli, T. E., Fyhrie, D. P., Schaffler, M. B., & Goldstein, S. A. (2000). Variations in Three-Dimensional Cancellous Bone Architecture of the Proximal Femur in Female Hip Fractures and in Controls. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.2000.15.1.32

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.