The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Synchrotron Radiation Microtomography Allows the Analysis of Three-Dimensional Microarchitecture and Degree of Mineralization of Human Iliac Crest Biopsy Specimens: Effects of Etidronate Treatment
Abstract
Quantitative microcomputed tomography using synchrotron radiation (SR μCT) was used to assess the effects of a sequential etidronate therapy on both three-dimensional (3D) microarchitecture and degree of mineralization of bone (DMB) in postmenopausal osteoporosis. Thirty-two iliac crest biopsy specimens were taken from 14 patients with osteoporosis (aged 64 ± 1.8 years) before (baseline) and after 1 year of etidronate treatment, and after 2 years of treatment for four of the patients. The samples were imaged at high spatial resolution (voxel size = 10 μm) using the microtomography system developed at the European Synchrotron Radiation Facility (ESRF), Grenoble, France. Three-dimensional microarchitecture parameters were calculated and compared with those obtained from conventional histomorphometry. In addition, the DMB was evaluated also in 3D. No significant statistical changes regarding bone mass and structural parameters were observed in histomorphometry or 3D analyses. The distribution of the DMB in cortical and trabecular bone showed a trend to a shift toward highest mineralization values after 1 year of etidronate treatment (3.88% and 1.24% in cortical and trabecular bone, respectively). This trend was more evident after 2 years. The study also showed that SR μCT is an accurate technique and the only one for quantifying both the mineralization and the microarchitecture of bone samples at the same time in 3D.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Guidelines for assessment of bone microstructure in rodents using micro–computed tomography
Bouxsein, M. L., Boyd, S. K., Christiansen, B. A., Guldberg, R. E., Jepsen, K. J., & Müller, R. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.141 · Cited by 4,433
Bone mineralization density distribution in health and disease
Roschger, P., Paschalis, E. P., Fratzl, P., & Klaushofer, K. (2008) · Bone · doi:10.1016/j.bone.2007.10.021 · Cited by 648
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Constant mineralization density distribution in cancellous human bone
Roschger, P., Gupta, H. S., Berzlanovich, A., Ittner, G., Dempster, D. W., Fratzl, P., Cosman, F., Parisien, M., Lindsay, R., Nieves, J. W., et al. (2003) · Bone · doi:10.1016/s8756-3282(02)00973-0 · Cited by 273
Metadata
- Authors
- Nuzzo, S., Lafage-Proust, M. H., Martin-Badosa, E., Boivin, G., Thomas, T., Alexandre, C., & Peyrin, F.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-08-01
- Volume
- 17
- Issue
- 8
- Pages
- 1372-1382
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2012961078
- Cited by
- 171
- References
- 1
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synchrotron Radiation Microtomography Allows the Analysis of Three-Dimensional Microarchitecture and Degree of Mineralization of Human Iliac Crest Biopsy Specimens: Effects of Etidronate Treatment. https://app.cochat.ai/papers/10.1359/jbmr.2002.17.8.1372
- The paper
- Nuzzo, S., Lafage-Proust, M. H., Martin-Badosa, E., Boivin, G., Thomas, T., Alexandre, C., & Peyrin, F. (2002). Synchrotron Radiation Microtomography Allows the Analysis of Three-Dimensional Microarchitecture and Degree of Mineralization of Human Iliac Crest Biopsy Specimens: Effects of Etidronate Treatment. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.2002.17.8.1372
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.