Quantum efficiency independence of the time integrated emission from a fluorescent molecule
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The sensitivity of chemical or biological analyses using fluorescent tagged reagents is limited by concentration quenching of the fluorescence at high tag concentrations and by photochemical bleaching if high illumination intensities are used. This paper shows by theoretical analysis and experimental verification that concentration quenching lengthens bleaching lifetimes, and the integrated fluorescent emission obtained on complete bleaching is invariant with fluorescent quantum efficiency, absorption cross section, and the illumination's intensity and duration. This can be used to produce extremely sensitive fluorescent tagging procedes. The procedure also improves photometric reproducibility, allows a fluorescent stain to act as a probe of several properties in its microenvironment, and allows sample background differentiation even when the free stain background is more fluorescent than the bound one.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fluorescent complex between ethidium bromide and nucleic acids
Pecq, J. B. L., & Paoletti, C. (1967) · Journal of Molecular Biology · doi:10.1016/0022-2836(67)90353-1 · Cited by 2,534
Bardawil, W. A., & Toy, B. L. (1969) · American Journal of Clinical Pathology · doi:10.1093/ajcp/52.1.99b · Cited by 1,562
Fluorescence Activated Cell Sorting
Bonner, W. A., Hulett, H. R., Sweet, R. G., & Herzenberg, L. A. (1972) · Review of Scientific Instruments · doi:10.1063/1.1685647 · Cited by 777
Fluorescence assay in biology and medicine
Udenfriend, S. (1962) · Medical Entomology and Zoology · Cited by 772
Stryer, L. (1968) · Science · doi:10.1126/science.162.3853.526 · Cited by 705
Optical microscopic observation of single small molecules
Hirschfeld, T. (1976) · Applied Optics · doi:10.1364/ao.15.002965 · Cited by 287
Self-citation
Cited by
Fluorescence Spectroscopy of Single Biomolecules
Weiss, S. (1999) · Science · doi:10.1126/science.283.5408.1676 · Cited by 2,046
[18] Fluorescence resonance energy transfer and nucleic acids
Clegg, R. M. (1992) · Methods in Enzymology · doi:10.1016/0076-6879(92)11020-j · Cited by 735
Photobleaching kinetics of fluorescein in quantitative fluorescence microscopy
Song, L., Hennink, E. J., Young, I. T., & Tanke, H. J. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80442-x · Cited by 654
Subtypes of the Somatostatin Receptor Assemble as Functional Homo- and Heterodimers
Rocheville, M., Lange, D. C., Kumar, U., Sasi, R., Patel, R. C., & Patel, Y. C. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.275.11.7862 · Cited by 527
Quantitative assessment of fluorescent proteins
Cranfill, P. J., Sell, B. R., Baird, M. A., Allen, J. R., Lavagnino, Z., de Gruiter, H. M., Kremers, G.-J., Davidson, M. W., Ustione, A., & Piston, D. W. (2016) · Nature Methods · doi:10.1038/nmeth.3891 · Cited by 497
Metadata
- Authors
- Hirschfeld, T.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1976-12-01
- Volume
- 15
- Issue
- 12
- Pages
- 3135
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1980906534
- Cited by
- 170
- References
- 6
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.