The DOI matches its Crossref record.
Total hemispherical emissivities of copper, aluminum, and silver
Abstract
The temperature variation of the total hemispherical emissivities of Cu, Al, and Ag has been studied by using a temperature decay method in the 150-1000-K range. The results obtained are found to support, for the first time, a classical relaxation theory developed by Parker and Abbott. The experimental emissivity data are used to calculate the emissive relaxation times tau for Cu, Al, and Ag at various temperatures in this range. These tau values are found to be practically insensitive to temperature, a behavior contrary to that shown by the electrical relaxation times calculated from the resistivity vs temperature data of these metals.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ramanathan et al. demonstrated that the emission relaxation time of copper, aluminum, and silver remained largely independent of temperature.
“The study demonstrated that the “emission relaxation time” of the materials remained largely independent of temperature, indicating strong temperature insensitivity.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [36]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 6
- Davisson, 1924, J. Opt, Soc. Am., 8, 581, 10.1364/JOSA.8.000581 · DOI
- Ramanathan, 1977, J. Opt. Soc. Am., 67, 32, 10.1364/JOSA.67.000032 · DOI
- Estalote, 1977, J. Opt. Soc. Am., 67, 39, 10.1364/JOSA.67.000039 · DOI
- Best, 1949, J. Opt. Soc. Am., 39, 1009, 10.1364/JOSA.39.001009 · DOI
- Zuppardo, 1971, J. Opt. Soc. Am., 61, 1607, 10.1364/JOSA.61.001607 · DOI
- Pawlek, 1966, Cryogenics, 6, 14, 10.1016/S0011-2275(96)90056-9 · DOI
Cited by
Sorted by citations
Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review
Li, B., & Shen, F. (2026) · Cryo · doi:10.3390/cryo2010004 · Cited by 1
Metadata
- Authors
- Ramanathan, K. G., Yen, S. H., & Estalote, E. A.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1977-11-01
- Volume
- 16
- Issue
- 11
- Pages
- 2810
- ISSN
- 0003-6935
- 1539-4522
- Cited by
- 37
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review