The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Frequency-modulation spectroscopy for trace species detection: theory and comparison among experimental methods
Abstract
A variety of frequency-modulation methods for high-sensitivity absorption detection of gas-phase species has evolved in recent years. The distinctions among these methods are mostly semantic. The mathematical derivations for wavelength-modulation spectroscopy and one- and two-tone frequency-modulation spectroscopies are presented; a common terminology is used to permit a comprehensive comparison of predicted detection sensitivities. Applying this formalism, I compare the optimum detection sensitivities of these different methods for a typical laser system, using the same parameters. As long as residual amplitude modulation is minimized by proper adjustment of the detection phase angle, high-frequency wavelength modulation and one- and two-tone frequency-modulation methods all achieve approximately the same sensitivities. The choice among techniques is most strongly driven by the individual laser tuning characteristics, the absorption linewidth, and the detection bandwidth. It is shown that excess laser noise cannot always be excluded from consideration, even at megahertz detection frequencies. Also, detection at harmonics of the modulation or beat frequency may present certain advantages in minimizing residual amplitude-modulation noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency modulation (FM) spectroscopy: Theory of lineshapes and signal-to-noise analysis
Bjorklund, G. C., Levenson, M. D., Lenth, W., & Ortiz, C. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00688820 · Cited by 568
Quantum-limited laser frequency-modulation spectroscopy
Gehrtz, M., Whittaker, E. A., & Bjorklund, G. C. (1985) · Journal of the Optical Society of America B · doi:10.1364/josab.2.001510 · Cited by 201
Ouyang, X. Y., & Varghese, P. L. (1989) · Applied Optics · doi:10.1364/ao.28.001538 · Cited by 44
Cited by
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Werle, P., M�cke, R., & Slemr, F. (1993) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00425997 · Cited by 947
Infrared laser-absorption sensing for combustion gases
Goldenstein, C. S., Spearrin, R. M., Jeffries, J. B., & Hanson, R. K. (2017) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2016.12.002 · Cited by 701
Rieker, G. B., Jeffries, J. B., & Hanson, R. K. (2009) · Applied Optics · doi:10.1364/ao.48.005546 · Cited by 581
Tomographic absorption spectroscopy for the study of gas dynamics and reactive flows
Cai, W., & Kaminski, C. F. (2017) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2016.11.002 · Cited by 280
Metadata
- Authors
- Silver, J. A.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1992-02-20
- Volume
- 31
- Issue
- 6
- Pages
- 707
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2029555209
- Cited by
- 558
- References
- 3
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency-modulation spectroscopy for trace species detection: theory and comparison among experimental methods. https://app.cochat.ai/papers/10.1364/ao.31.000707
- The paper
- Silver, J. A. (1992). Frequency-modulation spectroscopy for trace species detection: theory and comparison among experimental methods. Applied Optics. https://doi.org/10.1364/ao.31.000707
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.