The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Condensed Monte Carlo simulations for the description of light transport
Open accessAbstract
A novel method, condensed Monte Carlo simulation, is presented that applies the results of a single Monte Carlo simulation for a given albedo micro(s)/(micro(alpha) & micro(s)) to obtaining results for other albedos; micro(s) and micro(alpha), are the scattering and absorption coefficients, respectively. The method requires only the storage of the number of interactions of each photon with the medium. The reflectance and transmittance of turbid slabs can thus be found from a limited number of condensed Monte Carlo simulations. We can use an inversion procedure to obtain the absorption and scattering coefficients from the total reflectance and total transmittance of slabs. Remitted photon densities from a semi-infinite medium as a function of the distance between the light source and the detector for all albedos can be found even from the results of a single condensed Monte Carlo simulation. The application of similarity rules may reduce further the number of Monte Carlo simulations that are needed to describe the influence of the distribution of scattering angles on the results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Kollias, N., Sayre, R. M., Zeise, L., & Chedekel, M. R. (1991) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/1011-1344(91)80147-a · Cited by 482
Cited by
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Measurement of the penetration depths of red and near infrared light in human “ex vivo” tissues
Stolik, S., Delgado, J. A., Pérez, A., & Anasagasti, L. (2000) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/s1011-1344(00)00082-8 · Cited by 468
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
Metadata
- Authors
- Graaff, R., Koelink, M. H., de Mul, F. F. M., Zijlstra, W. G., Dassel, A. C. M., & Aarnoudse, J. G.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1993-02-01
- Volume
- 32
- Issue
- 4
- Pages
- 426
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2059096050
- Cited by
- 184
- References
- 2
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Condensed Monte Carlo simulations for the description of light transport. https://app.cochat.ai/papers/10.1364/ao.32.000426
- The paper
- Graaff, R., Koelink, M. H., de Mul, F. F. M., Zijlstra, W. G., Dassel, A. C. M., & Aarnoudse, J. G. (1993). Condensed Monte Carlo simulations for the description of light transport. Applied Optics. https://doi.org/10.1364/ao.32.000426
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.