The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Technique for measuring the reflectance of irregular, submillimeter-sized samples
Abstract
Details are given of a technique for measuring the reflectance at near-normal incidence of small, irregular, submillimeter-sized samples from the far IR (40 cm(-1)) to the visible (40000 cm(-1)) between 10 and 300 K by using a modified Michelson interferometer or grating spectrometer. The sample and a reference mirror are mounted on nonreflecting cones. At the focus the size of the beam is larger than either the sample or the reference, so that the entire area of the sample is utilized. The positions are interchanged by a 90° rotation by using preset mechanical stops. The scattering caused by geometrical effects is corrected for by the in situ evaporation of gold or aluminum onto the sample. The effect of diffraction is estimated from Mie theory by assuming the sample and reference to be spheres. For frequencies above ≈ 40 cm(-1) and sample diameters of ≈ 1 mm with a detector field of view of 30°, the calculations show that the ratio of the backscattered intensities gives a good approximation of the specular reflectance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Optical Constants of Solids
(1985) · Elsevier eBooks · doi:10.1016/c2009-0-20920-2 · Cited by 20,926
Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen
Mie, G. (1908) · Annalen der Physik · doi:10.1002/andp.19083300302 · Cited by 11,537
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Light Scattering by Small Particles
Van de Hulst, H. C., & Twersky, V. (1957) · Physics Today · doi:10.1063/1.3060205 · Cited by 5,619
Wooten, F., & Davis, S. P. (1973) · American Journal of Physics · doi:10.1119/1.1987434 · Cited by 4,518
Infrared evidence for gap anisotropy in YBa2 Cu3 O7
Collins, R. T., Schlesinger, Z., Holtzberg, F., & Feild, C. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.422 · Cited by 193
Comments on the Optical Constants of Metals and an Introduction to the Data for Several Metals
Lynch, D. W., & Hunter, W. R. (1997) · Handbook of Optical Constants of Solids · doi:10.1016/b978-012544415-6.50015-7 · Cited by 186
Cited by
Optical Response of High-Dielectric-Constant Perovskite-Related Oxide
Homes, C. C., Vogt, T., Shapiro, S. M., Wakimoto, S., & Ramirez, A. P. (2001) · Science · doi:10.1126/science.1061655 · Cited by 1,734
Self-citationElectrodynamics of high-Tcsuperconductors
Basov, D. N., & Timusk, T. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.721 · Cited by 788
Self-citationThe pseudogap state in high- superconductors: an infrared study
Puchkov, A. V., Basov, D. N., & Timusk, T. (1996) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/8/48/023 · Cited by 338
Self-citationc-axis response ofYBa2Cu4O8: A pseudogap and possibility of Josephson coupling ofCuO2planes
Basov, D. N., Timusk, T., Dabrowski, B., & Jorgensen, J. D. (1994) · Physical Review B · doi:10.1103/physrevb.50.3511 · Cited by 252
Self-citationInterband optical conductivity of the [001]-oriented Dirac semimetalCd3As2
Neubauer, D., Carbotte, J. P., Nateprov, A. A., Löhle, A., Dressel, M., & Pronin, A. V. (2016) · Physical Review B · doi:10.1103/physrevb.93.121202 · Cited by 116
Metadata
- Authors
- Homes, C. C., Reedyk, M., Cradles, D. A., & Timusk, T.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1993-06-01
- Volume
- 32
- Issue
- 16
- Pages
- 2976
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2127263204
- Cited by
- 365
- References
- 7
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technique for measuring the reflectance of irregular, submillimeter-sized samples. https://app.cochat.ai/papers/10.1364/ao.32.002976
- The paper
- Homes, C. C., Reedyk, M., Cradles, D. A., & Timusk, T. (1993). Technique for measuring the reflectance of irregular, submillimeter-sized samples. Applied Optics. https://doi.org/10.1364/ao.32.002976
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.