CoChat

Fluorescence of coumarins and xanthenes after two-photon absorption with a pulsed titanium–sapphire laser

Fischer, A., Cremer, C., Stelzer, E. H. K. · 1995 · Applied Optics
Cited by 197

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Fluorescence emission after two-photon absorption of coumarins and xanthenes in an alcoholic solution was measured in the tuning range of a femtosecond-pulsed titanium-sapphire laser (750-840 nm). Xanthenes, which have a low one-photon absorption in the near UV, show a higher fluorescence signal after two-photon absorption than the UV-excitable coumarins. When fluxes of 10(28) photons/(cm(2) s) are used, the two-photon absorption cross sections for xanthenes are 1 order of magnitude higher than the two-photon absorption cross sections of the coumarins. Absolute cross sections have been estimated for three coumarins and three xanthenes. For the xanthenes a significant wavelength-dependent departure from the expected fluorescence intensity square law was observed. The coumarins follow the square-law dependence. The consequences of the findings are discussed for analytic and diagnostic methods. An especially important result is that the resolution in two-photon microscopy of xanthenes is worse than expected.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.34.001989

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Fischer, A., Cremer, C., & Stelzer, E. H. K.
Venue
Applied Optics
Published
1995-04-20
Volume
34
Issue
12
Pages
1989
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W1971745313
Cited by
197
References
1
FWCI
6.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.