The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Computed-tomography imaging spectrometer: experimental calibration and reconstruction results
Abstract
A temporally and spatially nonscanning imaging spectrometer is described in terms of computedtomography concepts, specifically the central-slice theorem. A sequence of three transmission sinusoidalphase gratings rotated in 60° increments achieves dispersion in multiple directions and into multiple orders. The dispersed images of the system's field stop are interpreted as two-dimensional projections of a three-dimensional (x, y, λ) object cube. Because of the size of the finite focal-plane array, this imaging spectrometer is an example of a limited-view-angle tomographic system. The imaging spectrometer's point spread function is measured experimentally as a function of wavelength and position in the field of view. Reconstruction of the object cube is then achieved through the maximum-likelihood, expectation-maximization algorithm under the assumption of a Poisson likelihood law. Experimental results indicate that the instrument performs well in the case of broadband and narrow-band emitters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
Review of snapshot spectral imaging technologies
Hagen, N., & Kudenov, M. W. (2013) · Optical Engineering · doi:10.1117/1.oe.52.9.090901 · Cited by 739
Plasmonic photon sorters for spectral and polarimetric imaging
Laux, E., Genet, C., Skauli, T., & Ebbesen, T. W. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.1 · Cited by 415
HSCNN+: Advanced CNN-Based Hyperspectral Recovery from RGB Images
Shi, Z., Chen, C., Xiong, Z., Liu, D., & Wu, F. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00139 · Cited by 339
Mait, J. N., Euliss, G. W., & Athale, R. A. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000409 · Cited by 289
Atmospheric pressure discharge filaments and microplasmas: physics, chemistry and diagnostics
Bruggeman, P., & Brandenburg, R. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/46/464001 · Cited by 283
Metadata
- Authors
- Descour, M., & Dereniak, E.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1995-08-01
- Volume
- 34
- Issue
- 22
- Pages
- 4817
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2109149397
- Cited by
- 261
- References
- 1
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computed-tomography imaging spectrometer: experimental calibration and reconstruction results. https://app.cochat.ai/papers/10.1364/ao.34.004817
- The paper
- Descour, M., & Dereniak, E. (1995). Computed-tomography imaging spectrometer: experimental calibration and reconstruction results. Applied Optics. https://doi.org/10.1364/ao.34.004817
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.