Measurement of tissue optical properties by time-resolved detection of laser-induced transient stress

Oraevsky, Alexander A., Jacques, Steven L., Tittel, Frank K.·1997·Applied Optics

Abstract

We report on a technique utilizing time-resolved detection of laser-induced stress transients for the measurement of optical properties in turbid media specifically suitable for biological tissues. The method was tested initially in nonscattering absorbing media so that it could be compared with spectrophotometry. The basis of this method is provided by the conditions of temporal stress confinement in the irradiated volume where the pressure generated in tissues heated instantly by laser pulses is proportional to the absorbed laser energy density, and the exponential profile of the initial stress distribution in the irradiated volume corresponds to the z-axial distribution of the absorbed laser fluence. Planar thermoelastic waves can propagate in water-containing media with minimal distortion, and their axial profiles can be detected by an acoustic transducer with sufficient temporal resolution. The acoustic waves induced by 14-ns laser pulses in nonscattering media, turbid gels, and tissues were measured by a piezoelectric transducer with a 3-ns response time. Temporal profiles of stress transients yielded z-axial distributions of the absorbed laser energy in turbid and opaque media, provided that the speed of sound in these media was known. The absorption and effective scattering coefficients of beef liver, dog prostate, and human aortic atheroma at three wavelengths, 1064 nm (in near infrared), 532 nm (visible), and 355 nm (near UV), were deduced from laser-induced stress profiles with additional measurements of total diffuse reflectance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.36.000402

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 298

Metadata

Authors
Oraevsky, A. A., Jacques, S. L., & Tittel, F. K.
Venue
Applied Optics
Published
1997-01-01
Volume
36
Issue
1
Pages
402
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W1972931284
Cited by
298
References
1
FWCI
9.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of tissue optical properties by time-resolved detection of laser-induced transient stress. https://app.cochat.ai/papers/10.1364/ao.36.000402
The paper
Oraevsky, A. A., Jacques, S. L., & Tittel, F. K. (1997). Measurement of tissue optical properties by time-resolved detection of laser-induced transient stress. Applied Optics. https://doi.org/10.1364/ao.36.000402

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.