Soft-x-ray polarimeter with multilayer optics: complete analysis of the polarization state of light
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The design of a versatile high-precision eight-axis ultrahigh-vacuum-compatible polarimeter is presented. This multipurpose instrument can be used as a self-calibrating polarization detector for linearly and circularly polarized UV and soft-x-ray light. It can also be used for the characterization of reflection or transmission properties (reflectometer) or polarizing and phase-retarding properties (ellipsometer) of any optical element. The polarization properties of Mo/Si, Cr/C, Cr/Sc, and Ni/Ti multilayers used in this polarimeter as polarizers in transmission and as analyzers in reflection have been investigated theoretically and experimentally. In the soft-x-ray range, close to the p edges of Sc, Ti, and Cr, resonantly enhanced phase retardation of the transmission polarizers of as much as 18 degrees has been measured. With these newly developed optical elements the complete polarization analysis of soft-x-ray synchrotron radiation can be extended to the water-window range from 300 to 600 eV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Henke, B. L., Gullikson, E. M., & Davis, J. C. (1993) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1993.1013 · Cited by 6,285
High Precision Scanning Ellipsometer
Aspnes, D. E., & Studna, A. A. (1975) · Applied Optics · doi:10.1364/ao.14.000220 · Cited by 723
X-ray absorption and dichroism of transition metals and their compounds
de Groot, F. M. F. (1994) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(93)02041-j · Cited by 677
Montcalm, C., Kearney, P. A., Slaughter, J. M., Sullivan, B. T., Chaker, M., Pépin, H., & Falco, C. M. (1996) · Applied Optics · doi:10.1364/ao.35.005134 · Cited by 95
Mertins, H.-C., Schäfers, F., Grimmer, H., Clemens, D., Böni, P., & Horisberger, M. (1998) · Applied Optics · doi:10.1364/ao.37.001873 · Cited by 63
Self-citationAngular and energy dependence of ion bombardment of Mo/Si multilayers
Voorma, H.-J., Louis, E., Bijkerk, F., & Abdali, S. (1997) · Journal of Applied Physics · doi:10.1063/1.365992 · Cited by 43
Cited by
Resonant elastic soft x-ray scattering
Fink, J., Schierle, E., Weschke, E., & Geck, J. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/5/056502 · Cited by 166
“The technique was initially applied in polarimeters to characterize the polarisation state of synchrotron radiation [47, 48].”
MethodSelf-probing of molecules with high harmonic generation
Haessler, S., Caillat, J., & Salières, P. (2011) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/44/20/203001 · Cited by 149
Metadata
- Authors
- Schäfers, F., Mertins, H.-C., Gaupp, A., Gudat, W., Mertin, M., Packe, I., Schmolla, F., Di Fonzo, S., Soullié, G., Jark, W., Walker, R., Le Cann, X., Nyholm, R., & Eriksson, M.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1999-07-01
- Volume
- 38
- Issue
- 19
- Pages
- 4074
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2068006340
- Cited by
- 219
- References
- 6
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Soft-x-ray polarimeter with multilayer optics: complete analysis of the polarization state of light. https://app.cochat.ai/papers/10.1364/ao.38.004074
- The paper
- Schäfers, F., Mertins, H.-C., Gaupp, A., Gudat, W., Mertin, M., Packe, I., Schmolla, F., Di Fonzo, S., Soullié, G., Jark, W., Walker, R., Le Cann, X., Nyholm, R., & Eriksson, M. (1999). Soft-x-ray polarimeter with multilayer optics: complete analysis of the polarization state of light. Applied Optics. https://doi.org/10.1364/ao.38.004074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.