The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Influence of optical properties on two-photon fluorescence imaging in turbid samples
Open accessAbstract
A numerical model was developed to simulate the effects of tissue optical properties, objective numerical aperture (N.A.), and instrument performance on two-photon-excited fluorescence imaging of turbid samples. Model data are compared with measurements of fluorescent microspheres in a tissuelike scattering phantom. Our results show that the measured two-photon-excited signal decays exponentially with increasing focal depth. The overall decay constant is a function of absorption and scattering parameters at both excitation and emission wavelengths. The generation of two-photon fluorescence is shown to be independent of the scattering anisotropy, g, except for g > 0.95. The N.A. for which the maximum signal is collected varies with depth, although this effect is not seen until the focal plane is greater than two scattering mean free paths into the sample. Overall, measurements and model results indicate that resolution in two-photon microscopy is dependent solely on the ability to deliver sufficient ballistic photon density to the focal volume. As a result we show that lateral resolution in two-photon microscopy is largely unaffected by tissue optical properties in the range typically encountered in soft tissues, although the maximum imaging depth is strongly dependent on absorption and scattering coefficients, scattering anisotropy, and objective N.A..
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Cited by
Non-Invasive In Vivo Characterization of Breast Tumors Using Photon Migration Spectroscopy
Tromberg, B. J., Shah, N., Lanning, R., Cerussi, A., Espinoza, J., Pham, T., Svaasand, L., & Butler, J. (2000) · Neoplasia · doi:10.1038/sj.neo.7900082 · Cited by 687
Self-citationHigh-resolution full-field optical coherence tomography with a Linnik microscope
Dubois, A., Vabre, L., Boccara, A.-C., & Beaurepaire, E. (2002) · Applied Optics · doi:10.1364/ao.41.000805 · Cited by 567
Two-photon microscopy in brain tissue: parameters influencing the imaging depth
Oheim, M., Beaurepaire, E., Chaigneau, E., Mertz, J., & Charpak, S. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00438-1 · Cited by 425
Metadata
- Authors
- Dunn, A. K., Wallace, V. P., Coleno, M., Berns, M. W., & Tromberg, B. J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2000-03-01
- Volume
- 39
- Issue
- 7
- Pages
- 1194
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1980285018
- Cited by
- 182
- References
- 1
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of optical properties on two-photon fluorescence imaging in turbid samples. https://app.cochat.ai/papers/10.1364/ao.39.001194
- The paper
- Dunn, A. K., Wallace, V. P., Coleno, M., Berns, M. W., & Tromberg, B. J. (2000). Influence of optical properties on two-photon fluorescence imaging in turbid samples. Applied Optics. https://doi.org/10.1364/ao.39.001194
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.