The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities
Abstract
We show that the artificial resonances of dielectric optical cavities can be used to enhance the detection sensitivity of evanescent-wave optical fluorescence biosensors to the binding of a labeled analyte with a biospecific monolayer. Resonant coupling of power into the optical cavity allows for efficient use of the long photon lifetimes (or equivalently, the high internal power) of the high-Q whispering gallery modes to increase the probability of photon absorption into the fluorophore, thereby enhancing fluorescence emission. A method to compare the intrinsic sensitivity between resonant cavity and waveguide formats is also developed. Using realistic estimates for dielectric cylindrical cavities in both bulk and integrated configurations, we can expect sensitivity enhancement by at least an order of magnitude over standard waveguide evanescent sensors of equivalent sensing geometries. In addition, the required sample volume can be reduced significantly. The cylindrical cavity format is compatible with a large variety of sensing modalities such as immunoassay and molecular diagnostic assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silica-based planar lightwave circuits
Himeno, A., Kato, K., & Miya, T. (1998) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.736076 · Cited by 238
Cited by
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Metasurface Micro/Nano-Optical Sensors: Principles and Applications
Qin, J., Jiang, S., Wang, Z., Cheng, X., Li, B., Shi, Y., Tsai, D. P., Liu, A. Q., Huang, W., & Zhu, W. (2022) · ACS Nano · doi:10.1021/acsnano.2c03310 · Cited by 359
Optical ring resonators for biochemical and chemical sensing
Sun, Y., & Fan, X. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4237-z · Cited by 355
Whispering-gallery-mode electro-optic modulator and photonic microwave receiver
Ilchenko, V. S., Savchenkov, A. A., Matsko, A. B., & Maleki, L. (2003) · Journal of the Optical Society of America B · doi:10.1364/josab.20.000333 · Cited by 177
Metadata
- Authors
- Blair, S., & Chen, Y.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2001-02-01
- Volume
- 40
- Issue
- 4
- Pages
- 570
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2067229171
- Cited by
- 159
- References
- 1
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities. https://app.cochat.ai/papers/10.1364/ao.40.000570
- The paper
- Blair, S., & Chen, Y. (2001). Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities. Applied Optics. https://doi.org/10.1364/ao.40.000570
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.