The DOI matches its Crossref record.
Design and modeling of a photonic crystal fiber gas sensor
Open accessAbstract
We report the modeling results of an all-fiber gas detector that uses photonic crystal fiber (PCF). The relative sensitivity of the PCF as a function of the fiber parameters is calculated. Gas-diffusion dynamics that affect the sensor response time is investigated theoretically and experimentally. A practical PCF sensor aiming for high sensitivity gas detection is proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photonic crystal fibres for chemical sensing and photochemistry
Cubillas, A. M., Unterkofler, S., Euser, T. G., Etzold, B. J. M., Jones, A. C., Sadler, P. J., Wasserscheid, P., & Russell, P. S. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60128e · Cited by 300
Mishra, G. P., Kumar, D., Chaudhary, V. S., & Kumar, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3131694 · Cited by 114
Metadata
- Authors
- Hoo, Y. L., Jin, W., Shi, C., Ho, H. L., Wang, D. N., & Ruan, S. C.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2003-06-20
- Volume
- 42
- Issue
- 18
- Pages
- 3509
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2054853842
- Cited by
- 304
- References
- 0
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and modeling of a photonic crystal fiber gas sensor. https://app.cochat.ai/papers/10.1364/ao.42.003509
- The paper
- Hoo, Y. L., Jin, W., Shi, C., Ho, H. L., Wang, D. N., & Ruan, S. C. (2003). Design and modeling of a photonic crystal fiber gas sensor. Applied Optics. https://doi.org/10.1364/ao.42.003509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.