The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection
Abstract
Tunable-laser absorption spectroscopy in the mid-IR spectral region is a sensitive analytical technique for trace-gas quantification. The detection of nitric oxide (NO) in exhaled breath is of particular interest in the diagnosis of lower-airway inflammation associated with a number of lung diseases and illnesses. A gas analyzer based on a continuous-wave mid-IR quantum cascade laser operating at approximately 5.2 microm and on off-axis integrated cavity output spectroscopy (ICOS) has been developed to measure NO concentrations in human breath. A compact sample cell, 5.3 cm in length and with a volume of < 80 cm3, that is suitable for on-line and off-line measurements during a single breath cycle, has been designed and tested. A noise-equivalent (signal-to-noise ratio of 1) sensitivity of 10 parts in 10(9) by volume (ppbv) of NO was achieved. The combination of ICOS with wavelength modulation resulted in a 2-ppbv noise-equivalent sensitivity. The total data acquisition and averaging time was 15 s in both cases. The feasibility of detecting NO in expired human breath as a potential noninvasive medical diagnostic tool is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology of nitrogen oxides in the airways
Gaston, B., Drazen, J. M., Loscalzo, J., & Stamler, J. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.2.7508323 · Cited by 918
Cited by
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Wang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Analytical Chemistry of Nitric Oxide
Hetrick, E. M., & Schoenfisch, M. H. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155146 · Cited by 314
Metadata
- Authors
- Bakhirkin, Y. A., Kosterev, A. A., Roller, C., Curl, R. F., & Tittel, F. K.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2004-04-10
- Volume
- 43
- Issue
- 11
- Pages
- 2257
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2000332397
- Cited by
- 188
- References
- 1
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection. https://app.cochat.ai/papers/10.1364/ao.43.002257
- The paper
- Bakhirkin, Y. A., Kosterev, A. A., Roller, C., Curl, R. F., & Tittel, F. K. (2004). Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection. Applied Optics. https://doi.org/10.1364/ao.43.002257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.