Effective scattering coefficient of the cerebral spinal fluid in adult head models for diffuse optical imaging
The DOI matches its Crossref record.
Abstract
An efficient computation of the time-dependent forward solution for photon transport in a head model is a key capability for performing accurate inversion for functional diffuse optical imaging of the brain. The diffusion approximation to photon transport is much faster to simulate than the physically correct radiative transport equation (RTE); however, it is commonly assumed that scattering lengths must be much smaller than all system dimensions and all absorption lengths for the approximation to be accurate. Neither of these conditions is satisfied in the cerebrospinal fluid (CSF). Since line-of-sight distances in the CSF are small, of the order of a few millimeters, we explore the idea that the CSF scattering coefficient may be modeled by any value from zero up to the order of the typical inverse line-of-sight distance, or approximately 0.3 mm(-1), without significantly altering the calculated detector signals or the partial path lengths relevant for functional measurements. We demonstrate this in detail by using a Monte Carlo simulation of the RTE in a three-dimensional head model based on clinical magnetic resonance imaging data, with realistic optode geometries. Our findings lead us to expect that the diffusion approximation will be valid even in the presence of the CSF, with consequences for faster solution of the inverse problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Self-citationOptical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Metadata
- Authors
- Custo, A., Wells III, W. M., Barnett, A. H., Hillman, E. M. C., & Boas, D. A.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2006-07-01
- Volume
- 45
- Issue
- 19
- Pages
- 4747
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2006163783
- Cited by
- 147
- References
- 0
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effective scattering coefficient of the cerebral spinal fluid in adult head models for diffuse optical imaging. https://app.cochat.ai/papers/10.1364/ao.45.004747
- The paper
- Custo, A., Wells III, W. M., Barnett, A. H., Hillman, E. M. C., & Boas, D. A. (2006). Effective scattering coefficient of the cerebral spinal fluid in adult head models for diffuse optical imaging. Applied Optics. https://doi.org/10.1364/ao.45.004747
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.