Cited by 17Optical measurement and interference techniquesOptical and Acousto-Optic TechnologiesPhotorefractive and Nonlinear Optics

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Measurement of group refractive index wavelength dependence using a low-coherence tandem interferometer

Hirai, Akiko, Matsumoto, Hirokazu·2006·Applied Optics

Abstract

A technique for the measurement of the group refractive index wavelength dependence of optical materials using a low-coherence tandem interferometer and a spectrometer is proposed. Four channeled spectra resulting from interferences of light beams from different pairs of optical paths are used for the calculation of optical path differences. The group refractive index wavelength dependence is calculated from these optical path differences generated from the sample under measurement. No a priori information of the geometric thickness of a sample is required. The wavelength dependence of the group refractive index of the samples BK7 parallel plate of 5.200 and 10.025 mm from 675 to 850 nm is experimentally measured with an accuracy of the order of 10(-5) and a repeatability of the order of 10(-9).

Overview

Integrity signals

Registry

Crossref · 10.1364/ao.45.005614

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 16 references

Cited by

Sorted by citations

See all 17

Metadata

Authors
Hirai, A., & Matsumoto, H.
Affiliations
National Institute of Advanced Industrial Science and Technology (JP)
Venue
Applied Optics
Published
2006-08-01
Volume
45
Issue
22
Pages
5614
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2000129266
Cited by
17
References
16
Citations by year
2021: 3 · 2019: 1 · 2016: 1 · 2014: 3 · 2013: 1 · 2012: 2
FWCI
1.18
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Optics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Optical and Acousto-Optic Technologies
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
Keywords
group refractive index, wavelength dependence, optical path difference, spectrometer, BK7 glass, optical material characterization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review