Cited by 16Surface Modification and SuperhydrophobicityMinerals Flotation and Separation TechniquesFluid Dynamics and Heat Transfer

Improved inverted bubble method for measuring small contact angles at crystal-solution-vapor interfaces

Corti, Thierry, Krieger, Ulrich K.·2007·Applied Optics

Abstract

We propose and evaluate an improvement of the inverted bubble method, originally proposed by McLachlan and Cox [Rev. Sci. Instrum. 46, 80 (1975)], a technique for measuring small contact angles at crystal-solution-vapor interfaces on a gas bubble under a solid immersed in a test solution. A simple experimental setup is used to evaluate the proposed method. We conclude that the method is suitable for measuring small contact angles with a minimum detectable angle of about 3 degrees . Improvements in instrument design are proposed to lower the detection limit to 0.5 degrees or below.

Integrity signals

Registry

Crossref · 10.1364/ao.46.005835

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Corti, T., & Krieger, U. K.
Affiliations
  • ETH Zurich (CH)
  • Institute for Atmospheric and Climate Science (CH)
Venue
Applied Optics
Published
2007-08-09
Volume
46
Issue
23
Pages
5835
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2051238779
Cited by
16
References
0
Citations by year
2026: 2 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 1 · 2020: 1 · 2019: 2 · 2018: 1 · 2014: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Optics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Surface Modification and Superhydrophobicity
  • Physical Sciences › Environmental Science › Water Science and Technology › Minerals Flotation and Separation Techniques
  • Physical Sciences › Engineering › Computational Mechanics › Fluid Dynamics and Heat Transfer
Keywords
contact angle measurement, gas bubbles, instrument design, detection limit

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review