Multiple-object geometric deformable model for segmentation of macular OCT
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Optical coherence tomography (OCT) is the de facto standard imaging modality for ophthalmological assessment of retinal eye disease, and is of increasing importance in the study of neurological disorders. Quantification of the thicknesses of various retinal layers within the macular cube provides unique diagnostic insights for many diseases, but the capability for automatic segmentation and quantification remains quite limited. While manual segmentation has been used for many scientific studies, it is extremely time consuming and is subject to intra- and inter-rater variation. This paper presents a new computational domain, referred to as flat space, and a segmentation method for specific retinal layers in the macular cube using a recently developed deformable model approach for multiple objects. The framework maintains object relationships and topology while preventing overlaps and gaps. The algorithm segments eight retinal layers over the whole macular cube, where each boundary is defined with subvoxel precision. Evaluation of the method on single-eye OCT scans from 37 subjects, each with manual ground truth, shows improvement over a state-of-the-art method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001
Self-citation
Cited by
Srinivasan, P. P., Kim, L. A., Mettu, P. S., Cousins, S. W., Comer, G. M., Izatt, J. A., & Farsiu, S. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003568 · Cited by 513
Chiu, S. J., Allingham, M. J., Mettu, P. S., Cousins, S. W., Izatt, J. A., & Farsiu, S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001172 · Cited by 377
Karri, S. P. K., Chakraborty, D., & Chatterjee, J. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000579 · Cited by 313
Evaluating White Matter Lesion Segmentations with Refined Sørensen-Dice Analysis
Carass, A., Roy, S., Gherman, A., Reinhold, J. C., Jesson, A., Arbel, T., Maier, O., Handels, H., Ghafoorian, M., Platel, B., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-64803-w · Cited by 185
Self-citationStructured layer surface segmentation for retina OCT using fully convolutional regression networks
He, Y., Carass, A., Liu, Y., Jedynak, B. M., Solomon, S. D., Saidha, S., Calabresi, P. A., & Prince, J. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101856 · Cited by 104
“The second step in typical retinal layer segmentation methods is a post processing of the surface classification results using either level sets (Carass et al., 2014; Novosel et al., 2015; Carass and Prince, 2016; Novosel et al., 2017; Liu et al., 2018, 2019) or graph methods (Garvin et al., 2009;…”
MethodSelf-citation
Metadata
- Authors
- Carass, A., Lang, A., Hauser, M., Calabresi, P. A., Ying, H. S., & Prince, J. L.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2014-03-04
- Volume
- 5
- Issue
- 4
- Pages
- 1062
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2024492357
- Cited by
- 53
- References
- 2
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.